Autodesign sections
Autodesign sections are members that have been flagged as autodesigned within the Tekla Structural Designer software but have not undergone any part of the design process yet.
Revit will import any member which has been flagged as autodesigned as a TSD_Autodesign type. This is an I-section shape of 100mm depth (3.937”) and 60mm (2.362”) width.
We would recommend that the Tekla Structural Designer validation process is completed correctly and models are designed before performing any sort of export to Revit. This ensures that correctly designed section sizes are integrated.

It is also possible to export any member from Revit as being a TSD_Autodesign section. This imports the member into Tekla Structural Designer as the default section for the particular order file being used and with the AutoDesign check being enabled.
The option to do this is held within the Advanced Mapping dialog.

Truss members

Structural Truss elements within Revit are specialized items. All types within a truss family share the same profile layout with individual types specified within the truss hosting other parameters, such as the structural framing families used for modeling chords and web members.
Structural Truss elements are grouped together and displayed as a series of dashed blue lines. Structural Truss objects generally lock the type parameters for individual members and pin the sub-instances so that positions cannot be easily adjusted.
When it comes to the integration of Structural Truss instances, all trusses and instances held within the assembly will be exported from Revit and imported into Tekla Structural Designer as a series of individual truss members.
Please note however that due to a restriction of the Autodesk API, Structural Truss elements cannot be imported into Revit. This means that when design results are returned from Tekla Structural Designer, vertical elements will be altered to become Structural Column objects, the remaining objects are generated as Structural Framing instances.
Due to the limitations of Structural Truss objects and the pinning of the individual boom and strut instances, the update process will be unable to adjust material grades, section sizes or positions.
We would recommend that Structural Truss families be exploded to allow correct round tripping.
Plate Girders, Plated Columns, Fabsec Beams and Westok Plate Girders
Plated sections of varying depths and widths can be modeled within Revit by using the families installed as part of the Tekla Library. These are:
Plated Column
-
C:\ProgramData\Tekla\Structural\TSD Integrator\202x*\Tekla Library\Columns\Steel\Plate Column.rfa
Plate Girder Beam
-
C:\ProgramData\Tekla\Structural\TSD Integrator\202x*\Tekla Library\Framing\Steel\Plate Girder.rfa
Fabsec Beam
-
C:\ProgramData\Tekla\Structural\TSD Integrator\202x*\Tekla Library\Framing\Steel\Fabsec.rfa
Westok Plate Girder Beam
-
C:\ProgramData\Tekla\Structural\TSD Integrator\202x*\Tekla Library\Framing\Steel\Westok Plate Girder.rfa
* The above paths will vary according to the version of Revit installed.
It is also possible to use custom Revit families to show similar representations within the Revit project. Please note however that for mapping purposes, it is necessary to map the section type through the Advanced Mapping dialogs for Structural Column and Structural Framing families.

It should also be noted that the integration requires six specific parameters to be generated. These are:
-
Depth;d
-
Top flange breadth; bt
-
Bottom flange breadth; bb
-
Top flange thickness; tft
-
Bottom flange thickness; tfb
-
Web thickness; tw
These parameters must be generated for successful integration to occur.
Westok Ribbon Cut beams
Westok beams are a modern version of the traditional castellated beam, but far more flexible and with a greater range and depth of applications. They are primarily used within the UK region and manufactured by Kloeckner Metals.

Users of Revit may notice that they have four families that can be used to model Westok Sections.
Cellular Beam
-
C:\ProgramData\Autodesk\RVT 202x*\Libraries\UK\Structural Framing\Steel\Cellular Beam.rfa
Cellular Beam with un-Equidistant End Holes
-
C:\ProgramData\Autodesk\RVT 202x*\Libraries\UK\Structural Framing\Steel\Cellular Beam with un-Equidistant End Holes.rfa
Westok Ribbon Cut
-
C:\ProgramData\Tekla\Structural\TSD Integrator\202x*\Tekla Library\Framing\Steel\Westok Ribbon Cut.rfa
Westok Ribbon Cut Short
-
C:\ProgramData\Tekla\Structural\TSD Integrator\202x*\Tekla Library\Framing\Steel\Westok Ribbon Cut Short.rfa
* The above paths will vary according to the version of Revit installed.
We would advise that the family Westok Ribbon Cut.rfa is the correct file to be used for the following reasons:
-
Cellular Beam.rfa
Sets out all web openings incorrectly (from the center of the section) and calculates the beam depth incorrectly.
-
Cellular Beam with un-Equidistant End Holes.rfa
Sets out the web openings correctly but calculates the (fixed) depth using a formula which does not take account of ribbon cutting techniques.
-
Westok Ribbon Cut.rfa
Sets out the web openings correctly and allows for variable depths of tee sections. This is the correct family to use.
-
Westok Ribbon Cut Short.rfa
This should only be used for automated import processes where designers have mistakenly generated extremely short Ribbon Cut Westok sections within Tekla Structural Designer and no cellular openings would be present.
When using the family Westok Ribbon Cut.rfa, users may note that there are a number of parameters that require details. These are detailed as following
| Construction Parameters | |
|---|---|
| h1 |
Half of the Cellular Hole Diameter (can be auto-calculated from parameter Do) |
| h2 |
Half of the Cellular Hole Diameter (can be auto-calculated from parameter Do) |
| Setback Right | User defined distance to make allowance of the difference between the analytical length and cut (solid) length of the beam. |
| Setback Left | User defined distance to make allowance of the difference between the analytical length and cut (solid) length of the beam. |
| S1 | Dimension from the start end of the cut shape to the center of the first cellular opening. |
| S | Cellular Hole Horizontal Spacing (Hole Centers) |
| Do | Cellular Hole Diameter |
| Structural Parameters | |
|---|---|
| Name1 | The ‘TYPE’ value (section name) of the upper tee section. |
| W1 | Section weight (kg/m) of the upper tee section |
| Name2 | The ‘TYPE’ value (section name) of the lower tee section. |
| W2 | Section weight (kg/m) of the lower tee section |
| If these parameters are set to unrecognized section names, then mapping problems may occur related to the Westok Tee section. The Westok Tee entry should be mapped to a recognized UB, UC or Corus Advanced equivalent section. If the Westok Tee section is not correctly mapped then no information will be set for the beam. | |
| Dimension Parameters | |
|---|---|
| Top Base Member | |
| d1 | The overall depth of the upper section. |
| bf1 | The flange width of the upper section. |
| tf1 | The flange thickness of the upper section. |
| tw1 | Web thickness of the upper section. |
| k1 | The distance of the flange thickness added to the root radius. |
| Dimension Parameters | |
|---|---|
| Bottom Base Member | |
| d2 | The overall depth of the lower section. |
| bf2 | The flange width of the lower section. |
| tf2 | The flange thickness of the lower section. |
| tw2 | Web thickness of the lower section. |
| k2 | The distance of the flange thickness added to the root radius. |
Portal Frames
Portal Frames are specialized long span, low-rise moment frames generally used in the UK construction market. Portal Frame objects in Tekla Structural Designer are modeled as a single element that contains the stanchions, rafters and haunch objects.
Please note that Portal Frame objects are entirely different from regular moment frames modeled from several column and beam elements.

As these frames are modeled as one item within Tekla Structural Designer, there are some rules governing the integration transfer into Revit.
-
Portal Frame objects can only be exported from Tekla Structural Designer and imported into Revit. They cannot be exported from Revit and imported into Tekla Structural Designer.
-
Eaves haunches and apex haunches will not be transferred by the integration process, as there are no corresponding objects within Revit that can be used.
-
Portal Frame objects will be ‘exploded’ on export into the constituent Structural Column and Structural Framing instances.
Floor elements
Floor objects will be mapped from Revit to Tekla Structural Designer with the outline of the resulting slab being identical to the analytical outline within the Revit model.
For this reason, it is important to ensure that slabs are analytically connected (see previous section) and some simple rules are followed.
-
Floors with two distinct outlines in a single floor definition will not be exported. Please use two separate floor instances within Revit if this is the intent.

-
Avoid curved edges abutting curved edges. This may on occasion cause issues with the processing of the analysis wire. Try to separate curved edges with a small linear edge (We recommend a minimum length of 3/32” (or 3mm)).

-
Ensure that the floor outline does not self-intersect.
-
Openings sketched as part of the slab outline are beyond the scope of the integration process. Use the commands Shaft Opening, Vertical Opening or Opening by Face to model any hole requirements.
Openings drawn as part of the floor boundary will not be transferred although the opening intent will be shown as a sketched outline.
Floors should ideally be created so that a minimum of 2” or 50mm exists from the edge of any opening, or from the outline of any column member to the edge of the slab.
These distances will ensure that the floor slab can be correctly meshed when the analysis stage is performed in Tekla Structural Designer.
If these minimum distances cannot be met within the Revit software, consider removing the floor instance from the integration process and instead have the engineer generate the slab within the Tekla Structural Designer software to meet his or her own requirements.
Walls
Concrete Wall elements
Concrete Wall elements in Autodesk Revit are exported to Tekla Structural Designer based on the Structural Usage setting:
-
Non-bearing: Omits the wall instance from the Integration process.
-
Bearing : Exports the wall as a Bearing Wall element.
-
Shear : Exports the wall as a Concrete Wall element.
-
Structural Combined: Exports the wall as a Concrete Wall element.

In addition to this setting, the Function property (listed under Type properties) must be set as either an Interior wall, Exterior wall or Core-Shaft wall. All other Function settings will result in the wall being omitted from the export process.

We would strongly recommend that all users are aware of the analytical differences between a Bearing Wall and a Concrete Wall.
Please note that Wall instances are ALWAYS initially created in Revit as Bearing walls, the Structural Usage field cannot be modified until the wall has been generated.

Bearing Walls
Bearing Wall elements create a number of internal vertical elements (with a base minimum of five elements), based on the aspect ratio of the wall.
-
The lower the wall height, the more vertical elements will be created.
More vertical elements per wall will have an effect on the performance of the import into Tekla Structural Designer, and the creation (and validation) of the solver model.
The use and position of Bearing Walls needs to be considered with care as they offer only limited structural capabilities.
Masonry Walls
From Tekla Structural Designer to Autodesk Revit
Masonry walls are imported into Autodesk Revit with masonry wall grout and horizontal and vertical reinforcement information for each individual panel and panel patch.

Masonry wall material mapping: From Tekla Structural Designer to Autodesk Revit
During import processes, the Mapping - Material Grades dialog displays Tekla Structural Designer masonry wall grades (Import Name) alongside their corresponding Concrete Masonry Unit (CMU) material (Revit Name).

If a suitable material exists within the Revit model or template, the Integrator automatically sets the Revit Name to the corresponding masonry type.
If a specific material grade does not exist within the Revit model or template, the integrator creates a new material grade based on the material type Concrete Masonry Units. The new material will be assigned a suitable name and a warning will be shown in the log file (see following image).

If required, the mapping selection can be modified via the Revit Name dropdown. Only masonry classification material containing one structural layer will be available for selection.
Please note that the Advanced button is disabled and hidden for Masonry material.

If an imported model contains a generated masonry wall grade (see section above) and a new Revit masonry type is required, it is possible to either select an existing masonry type in the model or template (see image above) or manually enter a masonry type name directly into the Revit Name field (see following image).

Masonry wall material mapping: From Autodesk to Revit Tekla Structural Designer
When exporting a model from Autodesk Revit to Tekla Structural Designer, the material mapping grid displays Masonry wall material (Revit Name) alongside their corresponding Tekla Structural Designer masonry wall grades (Export Name).
If mapping can be determined, the Revit Name and Export Name fields are populated and locked.

If the Revit Name has been modified prior to export, the mapping process cannot be automated. In this case, the Export Name can be selected from a selection of Concrete grades. This will also include Masonry wall grades:

A custom masonry grade can be used by directly entering the information into the Export Name field.
Please note that the Export Name must match the Tekla Structural Designer custom masonry grade when importing into Structural Designer.

Foundation objects

Structural Foundation objects
Autodesk has changed Structural Foundation instances to be no longer considered structurally significant. This object category will not be considered for inclusion in the analytical model.
Due to this limitation, we provide support for Floor objects as these can provide bi-directional integration along with supporting alterations to sizes, eccentricities and pile positions.
Foundations imported from Tekla Structural Designer
Foundation objects can be integrated from Tekla Structural Designer to Autodesk Revit. These objects include:
-
Pad Base Column objects
-
Strip Base Wall objects
-
Pile Cap Column objects
These objects are integrated as floor objects and although the instance is initially created from the import from Tekla Structural Designer, size alterations made inside Autodesk Revit may be returned.
No foundation objects created from scratch with Autodesk Revit can be integrated into Tekla Structural Designer due to the limitation listed in the section above.
Foundation Piles imported from Tekla Structural Designer
Piles modeled in Tekla Structural Designer will be integrated as individual Structural Column instances into Autodesk Revit. Changes made to the piling configuration such as numbers of piles, pile location, pile shapes or piling lengths will be maintained and returned to Tekla Structural Designer, albeit as a new piling type within the software.
No piles created from scratch with Autodesk Revit will be integrated into Tekla Structural Designer.
Column Drop Objects
Column drops are imported from Tekla Structural Designer into Autodesk Revit as Floor objects. The shape of the drop head is controlled by Tekla Structural Designer, so although the object can be returned from Autodesk Revit, no size alterations can be returned.
No drop heads created from scratch with Autodesk Revit can be integrated into Tekla Structural Designer.