Category: Numbering
When
XS_BOLT_DUPLICATE_IGNORE is set to
TRUE, use
XS_BOLT_DUPLICATE_TOLERANCE to set the location tolerance that defines which bolt holes are considered duplicates and will therefore be ignored in part numbering.
The default value for the tolerance is 3 mm.
Note:
It is not recommended to change this advanced option during a project, but if you do so, you must carry out full numbering.
This advanced option is model specific and the setting is saved in the options database.