Category in Advanced options dialog: Analysis and design

Use this advanced option to set a limit angle between physical part and analysis model member, in order to test the validity of the analysis model. When the angle is greater than the limit, a message appears and a warning is added to the log. Small differences in angles are usual in the analysis model of a truss, for example. The default value is 10.0.

This advanced option is model specific and the setting is saved in the options database.