Skip to main content

Purlin 1 (61)

Modified: 5 Jun 2025 Tekla Structures 2026
2026
Tekla Structures

Purlin 1 (61) connects a column or a beam to one or two purlins with a bolted shear tab.

Objects created

  • Shear tab

  • Bolts

  • Welds

Use for

Situation Description

Beam is connected to two purlins with a bolted shear tab.

Selection order

  1. Select the main part (column or beam).

  2. Select the first secondary part.

  3. Select the second secondary part, if needed.

  4. Click the middle mouse button to create the connection.

Part identification key

Description

1

Shear tab

Picture tab

The Picture tab shows the connection with two secondary parts.

Parts tab

Use the Parts tab to define the part properties.

Parts

Option Description

Shear plate

Thickness of the shear tab.

Option

Description

Default

Pos_No

Prefix and start number for the part position number.

Some components have a second row of fields where you can enter the assembly position number.

The default part start number is defined in the Components settings in File menu > Settings > Options.

Material

Material grade.

The default material is defined in the Part material box in the Components settings in File menu > Settings > Options.

Name

Name that is shown in drawings and reports.

Parameters tab

Use the Parameters tab to define the connection dimensions.

Dimensions

Description

1

Shear tab offset from the main part center line.

2

Vertical cut of the secondary part to the main part edge.

3

Horizontal cut of the secondary part to the main part edge.

Shear tab side

Option Description

Shear tab is created on the right side.

This is the default option.

Shear tabs are created on both sides.

Shear tab is created on the left side.

Bolts tab

Use the Bolts tab to define the bolt group dimensions and the bolt properties.

Bolt group dimensions

Description

1

Bolt edge distance.

Edge distance is the distance from the center of a bolt to the edge of the part.

2

Number of bolts.

3

Bolt spacing.

Use a space to separate bolt spacing values. Enter a value for each space between bolts. For example, if there are 3 bolts, enter 2 values.

4

Dimension for horizontal bolt group position.

5

Dimension for vertical bolt group position.

One secondary part

If there is only one secondary part, select whether to create bolts or holes.

Bolt basic properties

Option

Description

Default

Bolt size

Bolt diameter.

Available sizes are defined in the bolt assembly catalog.

Bolt standard

Bolt standard to be used inside the component.

Available standards are defined in the bolt assembly catalog.

Tolerance

Gap between the bolt and the hole.

Thread in mat

Defines whether the thread may be within the bolted parts when bolts are used with a shaft.

This has no effect when full-threaded bolts are used.

Yes

Bolt type

Select the bolt type to define the location where the bolts should be attached.

Slotted holes

You can define slotted, oversized, or tapped holes.

Option

Description

Default

1

Vertical dimension of slotted hole.

0, which results in a round hole.

2

Horizontal dimension of slotted hole, or allowance for oversized holes.

0, which results in a round hole.

Hole type

Slotted creates slotted holes.

Oversized creates oversized holes.

No hole does not create holes.

Tapped creates tapped holes.

Rotate Slots

When the hole type is Slotted, this option rotates the slotted holes.

Slots in

Part(s) in which slotted holes are created. The options depend on the component in question.

Bolt assembly

The selected check boxes define which component objects (bolt, washers, and nuts) are used in the bolt assembly.

If you want to create a hole only, clear all the check boxes.

To modify the bolt assembly in an existing component, select the Effect in modify check box and click Modify.

Bolt length increase

Define how much the bolt length is increased. Use this option when, for example, painting requires the bolt length to be increased.

Sbolts tab

Use the Sbolts tab to define the bolt group dimensions and the bolt properties for the second secondary part.

Bolt group dimensions

Description

1

Dimension for horizontal bolt group position.

2

Bolt edge distance.

Edge distance is the distance from the center of a bolt to the edge of the part.

3

Number of bolts.

4

Bolt spacing.

Use a space to separate bolt spacing values. Enter a value for each space between bolts. For example, if there are 3 bolts, enter 2 values.

5

Dimension for vertical bolt group position.

Bolt basic properties

Option

Description

Default

Bolt size

Bolt diameter.

Available sizes are defined in the bolt assembly catalog.

Bolt standard

Bolt standard to be used inside the component.

Available standards are defined in the bolt assembly catalog.

Tolerance

Gap between the bolt and the hole.

Thread in mat

Defines whether the thread may be within the bolted parts when bolts are used with a shaft.

This has no effect when full-threaded bolts are used.

Yes

Bolt type

Select the bolt type to define the location where the bolts should be attached.

General tab

Click the link below to find out more:

General tab

Analysis tab

Click the link below to find out more:

Analysis tab

Submit