Skip to main content

Create fixed profiles

Modified: 14 Aug 2026 Tekla Structures 2026
2026
Tekla Structures

You can create completely new fixed profiles or create copies of existing fixed profiles. You can also convert parametric profiles into fixed profiles.

Create a fixed profile in the new profile catalog

You can create fixed profiles with a single cross section or with multiple cross sections.

Cross sections affect the total weight of the profile.

Warning:

If you create a profile with multiple cross sections, create the cross sections with the same number of corner points and in the same order.

  1. On the File menu, click Catalogs > Profile catalog to open the Modify Profile Catalog dialog box.
  2. Right-click the list of profiles, then select Add Profile.
  3. In the window that opens, enter a name for the profile, then click Add.

    The profile name must be unique and must not contain spaces.

  4. Define the properties of the profile.
    1. From the Profile type list, select User-defined, fixed.
    2. From the Profile subtype list, select the cross section that you want to use.

      If you have created your own user-defined cross sections, you can use one of them.

    3. Under Equivalent type, select a profile type that matches the new cross section as closely as possible. This is important because some connections only work for certain types of profiles.

      The equivalent type and the profile dimensions, such as height and width, affect which connections can be applied to the profile. An unsuitable equivalent type or missing dimension values may result in problems with connections.

  5. To modify the dimension values, double-click the Value cell, then enter the value.

    Always enter values for the dimensions Height h and Width b, as these values affect how Tekla Structures displays the profiles. If the values are 0, the part is drawn as a line.

  6. If you need to add an end cross section, click the +Add cross section icon next to the Cross section at list.

    A cross section with a Relative location of 1 is added to the list. This value indicates the location of the cross section along the axis: 0.0 for the start point and 1.0 for the end point. If the profile only has a single cross section, you do not need to add an end cross section.

  7. If you need to add more cross sections, click the + next to the Cross section at list and define the Relative location of each cross section.
    • If you want to use a different cross section in the profile, select a new one from the Profile subtype list.
    • If you want to remove a cross section, select the cross section from the list, then click the Delete cross section icon.
  8. Save the changes to the profile catalog.

Example

For a pitched profile, you need two cross sections with the same center point height. The Relative location value is 0.0 for the first cross section, 0.5 for the second cross section, and 1.0 for the third cross section.

Create a fixed profile in the original profile catalog

You can create fixed profiles with a single cross section or with multiple cross sections.

Cross sections affect the total weight of the profile.

Warning:

If you create a profile with multiple cross sections, create the cross sections with the same number of corner points and in the same order.

  1. On the File menu, click Catalogs > Profile catalog to open the Modify Profile Catalog dialog box.
  2. Right-click anywhere in the list of profiles, then select Add Profile.

    A new fixed profile with the name PROFILE1 is created.

  3. Define the properties of the profile.
    1. In the Profile name field, enter a new name for the profile.

      The profile name must be in upper case letters, with no spaces. Tekla Structures automatically converts lower case letters to upper case letters.

    2. From the Profile type list, select User-defined, fixed.
    3. From the Profile subtype list, select the cross section that you want to use.

      If you have created your own user-defined cross sections, you can use one of them.

    4. Under Equivalent type, select a profile type that matches the new cross section as closely as possible. This is important because some connections only work for certain types of profiles.

      The equivalent type and the profile dimensions, such as height and width, affect which connections can be applied to the profile. An unsuitable equivalent type or missing dimension values may result in problems with connections.

    5. Click Update.
  4. Modify the dimension values.

    Always enter values for the dimensions Height h and Width b, as these values affect how Tekla Structures displays the profiles. If the values are 0, the part is drawn as a line.

  5. Under Cross section, define a relative location for each cross section.
    1. From the Number list, select the number of the cross section.
    2. In the Relative location field, enter the location of the cross section.

      This value indicates the location of the cross section along the axis: 0.0 for the start end and 1.0 for the second end. If you only have a single cross section, select 1 for Number and enter 0.000 for Relative location.

    3. After defining each cross section, click Update.
  6. Click Add to add more cross sections, if needed.
    • If you want to use a different cross section in the profile, select a new one from the Profile subtype list.
    • If you want to remove a cross section, select the cross section from the Number list, then click Remove.
  7. Save the changes to the profile catalog.

Example

For a pitched profile, you need two cross sections with the same center point height. The Relative location value is 0.0 for the first cross section, 0.5 for the second cross section, and 1.0 for the third cross section.

Create a fixed profile by copying an existing profile

You can create new fixed profiles by modifying a copy of an existing, similar profile.

  1. On the File menu, click Catalogs > Profile catalog to open the Modify Profile Catalog dialog box.
  2. Select a fixed profile that is similar to the one that you want to create.
  3. Right-click, then select Copy Profile.
  4. Enter a name for the new profile in one of these ways:
    • New profile catalog: In the window that opens, enter a name for the profile, then click Add.

      The profile name must be unique and must not contain spaces.

    • Original profile catalog: Replace the automatically generated name in the Profile name box with a new name for the profile.

      The profile name must be in upper case letters, with no spaces. Tekla Structures automatically converts lower case letters to upper case letters.

  5. Modify the profile properties on the General, Analysis, and User attributes tabs.
    • The General tab contains information about profile types and dimensions.

      Warning:

      Under Equivalent type, select a profile type that matches the new cross section as closely as possible. This is important because some connections only work for certain types of profiles.

      Always enter values for the dimensions Height h and Width b, as these values affect how Tekla Structures displays the profiles. If the values are 0, the part is drawn as a line.

      The equivalent type and the profile dimensions, such as height and width, affect which connections can be applied to the profile. An unsuitable equivalent type or missing dimension values may result in problems with connections.

    • The Analysis tab contains information about the properties used in structural analysis. The structure can be analyzed with different analysis software.

    • The User attributes tab is for viewing or entering user attributes for profiles.

  6. (Original profile catalog only) Click Update.
  7. Save the changes to the profile catalog.

Create a fixed profile based on a parametric profile

You can convert an existing parametric profile into a fixed profile.

  1. On the File menu, click Catalogs > Profile catalog to open the Modify Profile Catalog dialog box.
  2. Select a parametric profile from the list.
  3. Right-click, then select Add Profile.

A new standard fixed profile is created with the profile values of the parametric profile.

Modify a fixed profile

If necessary, you can modify existing fixed profiles.

Note:

The fixed profiles conform to industry standards. Only administrators should modify them.

You can use these tabs to modify different types of information about fixed profiles:

  • The General tab contains information about profile types and dimensions.

  • The Analysis tab contains information about the properties used in structural analysis. The structure can be analyzed with different analysis software.

  • The User attributes tab is for viewing or entering user-defined attributes for profiles.

  1. On the File menu, click Catalogs > Profile catalog to open the Modify Profile Catalog dialog box.
  2. Select a fixed profile to modify its properties.
  3. (Original profile catalog only) When you have finished modifying the profile, click Update.
  4. Save the changes to the profile catalog.
Submit

Table of Contents