CMF Standard Horizontal Cladding Support (31) - Parameters tab
Not version-specific
Tekla Structures
Environment
Not environment-specific
Use the Parameters tab in the CMF Standard Horizontal Cladding Support Properties panel to control how the connecting members are defined within Tekla Structures.
Image
| Option | Description | Default | Other | ||||
|---|---|---|---|---|---|---|---|
| CJR at | A mixture of CJR and CSR supports can be included within the same bay. This value determines the number/location of CJR's in the bay. This works inconjunction with the Cladding Support Rail at field to define the number of restraints in the bay. The greatest number on either field will determine the total number of struts. For example '4' in the CJR at and '1 3' in the Cladding Support Rail at will result in four struts at 1/5 points and the first and third struts will be CSR's. | The default number of divisions will be determined appropriately from the data files for the bay length. | |||||
| Cladding Support Rail at | This value determines the number/location of CSR's. See above. | The default behaviour is to use CJR's only. | |||||
| Gauge (1.6mm, 2.0mm) | This specifies the thickness of the CJR to be used. | The default setting is 2mm. | |||||
| Channel Gauge (1.6mm, 2.0mm) | This specifies the thickness of the CSR to be used. | The default setting is 2mm. | |||||
| Use diagonal wires to column at | This sets the position in the arrangement where diagonal tie wires will be added to the first and last struts to the column connection. This is writen as a list of bay numbers for example, 1 3 would put diagonal tie wires in the first and third bay (see image). | The default behaviour is to not place any tie wires. |
Image
| ||||
| Use diagonal wires to mid struts at | This sets the position in the arrangement where diagonal tie wires will be added from the middle to the two adjacent struts. This is writen as a list of bay numbers for example, 1 3 would put diagonal tie wires in the first and third bay (see image). | The default behaviour is to not place any tie wires. |
Image
| ||||
| Face Strut to the (Left, Right) | This controls the direction of the strut created. If this is set to Left then looking from the first rail selected to the second, the rail support will be orientated so that the strut faces to the left. The Right option similarly causes the Rail Support to face to the right. | The default is set to Right. |
| ||||
| Top Cleat Bolt Grade | This sets the bolt standard for the strut connecting to the last rail. If left empty the general bolt grade will be used. | The default setting is 8.8XOX. | |||||
| General Bolt Grade | This sets the standard for all bolts added by the macro. | The default setting is 8.8XOX. | |||||
| Bottom Cleat Bolt Grade | This sets the bolt standard for the strut connecting to the first rail. If left empty the general bolt grade will be used. | The default setting is 8.8XOX. | |||||
| Class | This sets the class that all parts will be included in. | The default setting is 99. |
See more
CMF cold rolled - Important informationCMF Standard Horizontal Cladding Support (31)