You can use the plug-in Codes to profiles (ML052) to recognize/classify profiled profiles and to write the cross-section dimensions and the code of the profile to the user-defined attribute of the part.

Profiled profiles are profiles that have been profiled over the entire length.

The tool is used in conjunction with the saw list Reporting (ML112). The coding created in Codes to profiles (ML052) is used in Reporting (ML112).

 

Background information:
Special machines are needed to apply certain profiling to a timber profile. As not all factories have these machines, the profiling of such timber profiles is often outsourced. Desirable here is to recognize the profiled profiles in a model and then pull them out. 

This tool has been developed to recognize/classify (and subsequently extract) these profiled profiles

 

Principle:
Imagine the parts are displayed along the local X-axis and a light shines on them, projecting a shadow surface of the cross-section of the parts on a wall (the yellow area in the image below). 
The parts are classified as being profiled or non-profiled based on the shape of the shadow. 

In the image below, the red cross-section is rectangular. This profile is classified as non-profiled by the tool. 
The other cross-sections are non-rectangular. These profiles are therefore classified as profiled.

Image
052_012

 

Rules and conditions:

Each profile classified by the tool as profiled is assigned a Code prefix (string).

1e code = A
2e code = B
...

26e code = Z
27e code = AA
...

53e code = BA
...

If the profile is classified as profiled, the Code prefix and the Code dimensions are both written in the corresponding user-defined attribute.
The default value for the Code prefix is <empty>, or: unprofiled. If the dimension of the shadow area is equal to the defined profile cross-section, the profile is non-profiled and thus no information is written in the user-defined attribute.
If the part is classified as unprofiled, but the dimensions of the shadow area are different from the defined profile cross-section, then the defined profile cross-section is written in the corresponding user-defined attribute.
Back to top

Created objects

  • None
Back to top

Used for

SituationDescription
Image
M052_005
Wall plates with rounded edges
Image
Codes_to_profiles_ml052_006
Support profiles
Image
M052_007
Parts with cuts
Back to top

Before you start

Model profiled parts.

Back to top

Selection order

  1. Use the Select objects button to select the parts to be encoded.

General tab

In the "General" tab, all parameters can be defined.

Image
003

 

OptionDescription
Export
  • Selected part: All selected parts in the model are exported.
  • All parts: All parts in the model are exported.

Selection filter timber_partisprofiled: This selection filter ensures that only profiled parts are viewed/scanned. All rectangular profiles are therefore not viewed by the tool and this makes the tool much faster.

Contour plate prefixRandom plates are coded in a different way. By defining the prefix, the component knows which parts are modelled with a random plate.
Apply on

Specify the materials to which the export is to be applied. 

Options:

  • Timber
  • Steel
  • Concrete
  • Miscellaneous
Reset coding scheme

Indicate whether the existing codes should be reset. 

Options:

  • No - coding is not reset
  • Yes, re-issue all codes - everything will be recoded. This functionality can only be used if Export is set to All items.
  • Yes, only reset non-matching - profiled parts without a code prefix will be assigned a code prefix and code dimensions  after export.
Export pathFrom the export, the file CodesToProfiles.xml is created in which the coding is written. It is possible to change the location of the file here. If the file is deleted, the next time Codes to profiles (ML052) is executed, the coding is created completely anew. This will result in a complete reset of the coding.
Prefix assignment

It is possible to set the code prefix. 

Options:

Image
Codes_to_profiles_ml052_008

Profiles with the same profile but a different thickness are given the same code prefix.
Example:

Image
ML052_011
Image
Codes_to_profiles_ml052_009

Profiles with the same profile but a different thickness are given a different code prefix
Example:

Image
ML052_010

UDA tab

In the "UDA" tab you can define where the user-defined attributes (UDA's) are written.

Image
004

 

OptionDescription
Code prefixIn UDA name, specify where the Code prefix should be written. By default it is written in the UDA CODE_PREFIX.
DimensionsIn UDA name, specify where the Dimensions should be written. By default it is written in the UDA CODE_DIMENSIONS.

About tab

Information about the "build" date of the tool. This date may differ from the date in the tool you are using, but the content may nevertheless be the same. This date may be required when you contact the helpdesk.

Image
005

All rights reserved. No conclusions can be associated to the representation of the pictures in relation to the operating systems under which Tekla Structures runs.

This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. To view a copy of this license, visit http://creativecommons.org/licenses/by-nc-nd/4.0/ or send a letter to Creative Commons, 444 Castro Street, Suite 900, Mountain View, California, 94041, USA. 