Kingspan Apex Tie Bay (12)
Not version-specific
Tekla Structures
Environment
Not environment-specific
The Kingspan Apex Tie Bay macro can be used to define multiple ties within a bay, between the two Multibeams at an apex.
Before and after
Image
Image
Notes
- Any modification of the selected parts will cause this macro to be updated.
- Selected purlins must be facing each other.
- Selected purlins must have the same section depth.
- Both purlin sections must be parallel.
- Roof slopes must have the same pitch.
- When selecting two purlins, the shorter of the two must be selected first.
- When defining the bay you can either pick the rafters (as shown below) or just pick the Multibeams. If you just pick the Multibeams, the shortest Multibeam will define the bay size.
Selection order example
- Rafter (optional)
- Rafter (optional)
- Multibeam
- Multibeam
- Click middle mouse button
Image
See also
Kingspan cold rolled - Important informationKingspan Apex Tie Bay (12) - Parts tab
Kingspan Apex Tie Bay (12) - Parameters tab