Use the Parameters tab in the Metsec Standard Horizontal Cladding Support Properties panel to control how the connecting members are defined within Tekla Structures.
Image
| Option | Description | Default | Other | ||||
|---|---|---|---|---|---|---|---|
| PJR at | A mixture of PJR and cladding support rails can be included within the same bay. This value determines the number/location of PJR's in the bay. This works inconjunction with the Horizontal Cladding Support at (HCS) field to define the number of restraints in the bay. The greatest number on either field will determin the total number of struts. For example '4' in the PJR at and '1 3' in the HCS at field will result in four struts at 1/5 points and the first and third struts will be horizontal cladding supports. | The default number of divisions will be determined appropriately from the data files for the bay length. | |||||
| Horizontal Cladding Support at | This value determines the number/location of cladding support rails. See above. | The default behaviour is to use PJR's only. | |||||
| Face Strut to the (Left, Right) | This controls the direction of the strut created. If this is set to Left then looking from the sheeting face, the rail support will be orientated so that the strut faces to the left. The Right option similarly causes the rail support to face to the right. | The default is set to Right. |
| ||||
| Use diagonal wires to column at | This sets the position in the arrangement where diagonal tie wires will be added to the first and last struts to the column connection. This is writen as a list of bay numbers for example, 1 3 would put diagonal tie wires in the first and third bay (see image). | The default behaviour is to not place any tie wires. |
Image
| ||||
| Use diagonal wires to mid struts at | This sets the position in the arrangement where diagonal tie wires will be added from the middle to the two adjacent struts. This is writen as a list of bay numbers for example, 1 3 would put diagonal tie wires in the first and third bay (see image). | The default behaviour is to not place any tie wires. |
Image
| ||||
| PJR Profile Type (140J16, 140J20) | This sets the thickness of the PJR's that are placed between each pair of rails in the bay. | The default is set to 140J20. | |||||
| Sheeting Line Dist | This specifies an offset distance for the strut member. Postive numbers are towards the sheeting line. | The default distance will be determined appropriately from the model data. | |||||
| Top Cleat Bolt Grade | This sets the bolt standard for the strut connecting to the last rail. If left empty the general bolt grade will be used. | The default setting is 8.8XOX. | |||||
| General Bolt Grade | This sets the standard for all bolts added by the macro. | The default setting is 8.8XOX. | |||||
| Bottom Cleat Bolt Grade | This sets the bolt standard for the strut connecting to the first rail. If left empty the general bolt grade will be used. | The default setting is 8.8XOX. | |||||
| Group | This sets the class that all parts will be included in. | The default setting is 99. |