Thomas Panels Eaves Brace (54) - Parameters tab
Not version-specific
Tekla Structures
Environment
Not environment-specific
Use the Parameters tab in the Thomas Panels and Profiles Eaves Brace Properties panel to control how the connecting members are defined within Tekla Structures.
Image
| Option | Description | Default | Other |
|---|---|---|---|
| Top or Bottom (Top, Bottom) | This defines whether the eaves brace attaches to the top or bottom hole on the purlin. | The default is set to Bottom. | |
| Eaves Brace stiffener (No, Yes) | This is a simple field to indicate if the stiffener should be defined or not. | The default is set to No. | |
| General Bolt Grade | This sets the standard for all bolts added by the macro excluding those which may be placed to the web of the eaves beam. | The default setting is 8.8XOX. | |
| Eaves Beam Web Bolt Grade | This sets the standard for bolts placed to the web of the eaves beam. If this standard specifies countersunk bolts then a suitable packing plate will be added. | The default setting is 8.8XOX. | |
| Group | This sets the class that all parts will be included in. | The default setting is 99. |
See also
Thomas Panels cold rolled - Important informationThomas Panels Eaves Brace (54)
Thomas Panels Eaves Brace (54) - Parts tab