IDS Validator
On this page
Trimble Connect extension IDS Validator is designed to validate IFC files based on the rules captured in the corresponding IDS file, ensuring compliance with the standard required by the superior authority.
Learn more about IDS file format.
This help refers to version 0.5 of the extension. See tab page "About".
Back to topCS TC Extension package
IDS Validator belongs to the Construsoft Trimble Connect Extension package.
Back to topUse for
IDS Validator can be used either as a project extension or in the 3D viewer.
Back to topBefore you start
When using the extension in 3D viewer, firstly open the model.
(It is possible to choose a different model in IDS Validator then, but for visual representation of validated objects, it is better to open the model in which the objects will be validated.)
Validate tab
On the "Validate" tab, the IFC file(s) and IDS file(s) are selected from the project explorer.
| Option | Description | |
|---|---|---|
| 1 | Browser for IFC file(s) selection. | |
| 2 | Search the IFC files by name. | |
| 3 | Selected IFC file(s). | |
| 4 |
Image
| When the IFC file(s) are selected, the button for IDS files selection is enabled. Select IDS - select IDS files by which the selected IFC files will be validated in the dialog window. Pair by name - this option in drop-down button menu allows to pair all selected IFC files instantly with IDS files with the same name occurring in the same folder. |
|
Image
| Select loaded model file(s). The models opened in the 3D viewer are selected for the validation.
Available only for the extension in the 3D viewer. | |
|
Image
| Refresh the explorer. | |
|
Image
| Remove all selected IFC and IDS pairs. | |
| 5 | When the IFC and IDS pair(s) are selected, use the button "Validate" to perform the validation. | |
Multiple IFC files can be selected.
IFC files with different IDS files combinations can be validated together.
Validation results
The validation result(s) are displayed below the explorer window for each IFC file separately.
| Option | Description |
|---|---|
| 1 | Overflow menu. Options:
Image
|
For each validated IFC file, the results are inside the expandable section. Also, objects validated by each IDS file are listed separately in IDS specification.
| Option | Description | |
|---|---|---|
| 1 | Validation overview. These buttons work also as filters. | |
|
Image
| Number of all objects in the model. Click on it to show the list of all object types in the model. | |
|
Image
| Number of validated objects. Click on it to hide empty specifications. | |
|
Image
| Number of objects that succeeded. Click on it to filter only objects that succeeded. | |
|
Image
| Number of objects that failed. Click on it to filter only objects that failed. | |
| 2 | Overflow menu. Options:
| |
| 3 | Overflow menu. Options:
| |
Each IDS specification is expandable and the results are displayed.
The details about a validated object can be opened with valid or invalid parameters.
| Option | Description |
|---|---|
| 1 | Click on the icon to show the object in the model (available only when using the extension in the 3D viewer). Image
|
| 2 | Overflow menu available for failed objects. ToDo and BCF can be created. Options:
|
| 3 | The value of the property. |
| 4 | Show allowed values. Image
|
In the 3D viewer, the objects that have passed and failed the validation can be colorized according to the settings (see the "Settings" tab).
Supported IDS elements in requirements
- classification - supported also in applicability
- material - supported also in applicability
- partOf - supported also in applicability
- length
- maxLength
- minLength
- minOccurs
- maxOccurs
- maxInclusive
- maxExclusive
- minInclusive
- minExclusive
Learn more about IDS elements and how to use them in the official BuildingSMART IDS documentation.
Settings tab
On the "Settings" tab, set how the objects will be colorized and the CSV file will be exported.
| Option | Description |
|---|---|
| 1 | Coloring settings. Decide whether the valid and invalid objects should be colorized and choose the color. Decide whether the model should reset at the start of validation.
These settings are available only in the extension running in the 3D viewer. |
| 2 | Decide whether the model should reset at the start of validation.
These settings are available only in the extension running in the 3D viewer. |
| 3 | Set the transparency of the validated objects.
These settings are available only in the extension running in the 3D viewer. |
| 4 | Choose the columns exported in the CSV file. |
| 5 | Choose the divider used in the CSV file. |
| 6 | Decide whether only specifications containing results should be exported. |
| 7 | Decide whether the unvalidated objects should be listed at the end of CSV file. |
| 8 | Select the destination directory in project when the validation results are saved as CSV. |
About tab
On the "About" tab, general information about the extension and the developer can be found.
Version - check the version of the extension.
Documentation - find the instructions about the functionality on the TUA help page.
License Manager - manage your licenses in the License Manager.
Store - get the license for the extension and other tools in the Construsoft eshop!
All rights reserved. No conclusions can be associated to the representation of the pictures in relation to the operating systems under which Tekla Structures runs.
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. To view a copy of this license, visit http://creativecommons.org/licenses/by-nc-nd/4.0/ or send a letter to Creative Commons, 444 Castro Street, Suite 900, Mountain View, California, 94041, USA.