Salta al contenuto principale

Fire Proofing Calculator

Tekla Structures - Not version-specific fire proofing calculator fire proofing calculator fireproofing
Not version-specific
Tekla Structures
Environment
United States (Imperial)
United States (Metric)

1. Purpose and description

The Fire Proofing Calculator calculates the fireproofing thickness and flute fill volume per individual member in the Tekla model.  The formulas used for the tool are based on the 'Fire Resistance Directory Isolatek Designs' (ex. http://isolatek.com/designs_thickness/wb3_wb4/D902.pdf)

2. System requirements

Environments: Default, US Imperial, US Metric
Languages: English

3. Installation

To install the application:

  1. Make sure Tekla Structures is closed.
  2. Install the 32 or 64-bit (x64) installation. Download from the Tekla Warehouse.
  3. Reopen Tekla Structures once the installation is complete and you will see:
(Up to v21.1) A new toolbar icon will launch the tool...
Image
FireProofingCalculator_big.png
(v2016) A new thumbnail under Ungrouped items in the Applications & components side pane.
 
Image
2016_03_11_15_45_161.png

4. Interface

Image
snap05568.png
 

4.1 - Fire Proofing Options

  1. Reference Profile - Define the reference profile to be used in the calculation.  
  2. Rating System Thickness - Define the rating system thickness to be used in the calculation
  3. Calculation Mode - Choose the beam or column option to run depending on the selected objects.  The beam option will calculate the area of the profile using 3 sides to calculate the perimeter of the member assuming that the 4th side (top flange) will be covered in concrete.  The column options will calculate the area of the profile using 4 sides to calculate the perimeter of the member.

4.2 - Additional Options

  1. Calculate Flute? - If the Calculation Mode is set to Beam then you will have the option to calculate the flute or not.  
  2. Clear Existing Flute Attribute? - If the Calculation Mode is set to Beam then you will have the option to clear any existing flute attribute stored in the defined UDA.
  3. Flute Height - Define the flute height to be used in the calculation

4.3 - UDA Assignments

***Note:  On the Warehouse download page for this tool, you can also download the objects.inp file that has been created for the tool.  You can place it in the model folder or you can merge it with any existing customized objects.inp file that you may have in a system/firm folder.  DO NOT edit the system/environment objects.inp files.
  1. Fire Proofing - Define the UDA syntax to store the Fire Proofing thickness once it has been calculated. (FP_THK is the default syntax defined in the objects.inp file for this tool)
  2. Flute - Define the UDA syntax to store the flute volume once it has been calculated.  If the XS_IMPERIAL advanced option is set to TRUE then this value's units will be in3.  If it's set to FALSE then this value's units will be mm3.  (FP_FLUTE is the default syntax defined in the objects.inp file for this tool)

5.  Usage

  1. Define Fire Proofing Options, Additional Options, and UDA Assignments
  2. Select objects in the model to calculate
  3. Click the Calculate (Store To Selected) to store the fireproofing calculations to the selected objects
  4. The values will then be written to the UDA syntax defined in the UDA Assignments portion of the tool.

     

    Image
    snap05569.png

6. Notes on Calculations

The formulas used for the tool are based on the 'Fire Resistance Directory Isolatek Designs' (ex. http://isolatek.com/designs_thickness/wb3_wb4/D902.pdf)

Image
Fireproofing formula

5.1 Numerator

The numerator is a reference value that remains the same for all selected members.

  •  W2 - The second number from the Reference Profile ( i.e. 28 for a W8x28)
  •  D2 - The perimeter for the Reference Profile. For beams, the top flange width is excluded.
Image
Fireproofing Beam Section View
  •  T2 -  The Rating System Thickness 
Image
Fireproofing Example Rating Table

5.2 Denominator

The denominator is unique based on the profile of each selected member.

  • W1 -  The second value from the selected beam's or column's profile.
  • D1 - The perimeter of the selected beam or column - excluding the top flange width for a beam.

5.3 Flute

The user-provided Flute Height is multiplied by the calculated area of the beam's top flange.

 

 

Invia