US PEB Custom Variables
1. Purpose and description
This set of custom variables extends the reporting capabilities of Tekla Structures. These variables are available throughout the system: ie reports, marks as templates, drawings, .Net API, filtering, object representation, etc…
Back to top2. System requirements
Environments: Any
Languages: ENGLISH
Back to top3. Installation
To install the application:
- Run the appropriate US PEB Custom Variables installation file which is available in Tekla Warehouse.
- Have Tekla Structures closed during the installation.
- Reopen Tekla Structures once the installation is complete.
4. Usage
To use the application:
- You will need to have the prefix “CUSTOM.” in front of each variable where used.
- To use these variables in the Organizer they need to be added manually (see TUA article - Create a custom property in Organizer).
- These new variables should be added via a contentattributes_custom_usa_peb.lst to the appropriate folder and as an addition to the contentattributes.lst file.
4.1. Running X Dimensions
These variables provide valid bolt positions from the start (yellow handle) end of beam object(s) along the top flange, bottom flange, or web. Additional variations of the variables are provided via suffixes that allow for dimensions from the end-end of the beam, for different delimiters between values, and for the formatting of the values (see section 4.4).
|
Name |
Type |
Row Type |
Description |
|---|---|---|---|
|
CUSTOM.BOLTX_WEB |
String |
Part |
Provides running local x dimensions from the start-end for bolt groups in the web of the beam. Formatted according to unit settings and space delimited. For variations in numerical formats see section 4.4 below. |
|
CUSTOM.BOLTX_TOPFL |
String |
Part |
Provides running local x dimensions from the start-end for bolt groups in the top flange of the beam. Formatted according to unit settings and space delimited. For variations in numerical formats see section 4.4 below. |
|
CUSTOM.BOLTX_BTMFL |
String |
Part |
Provides running local x dimensions from the start-end for bolt groups in the bottom flange of the beam. Formatted according to unit settings and space delimited. For variations in numerical formats see section 4.4 below. |
|
*Variations: |
|
|
Add "_A" -> "_U" at the end for formatting string units, see Section 4.4 E.g. CUSTOM.BOLTX_WEB_A |
4.2. Punch Code Designations
These variables read the user-provided punch code rules (Sources\DT_PUNCH.SZ) and the hole positions from the selected beam object(s) to find matching patterns along the top flange, bottom flange, or web.
First, a comparison is made from the start (yellow handle) end for the "best" match -- first rule with the most matches -- which provides the first punch code character(s); these matching holes are then removed from the comparison list for the next step.
Second, a comparison is made from the end (magenta handle) end for the "best" match for the last punch code character(s); the matching holes are removed from the comparison list. The provided string includes the found punch code characters separated by a hyphen (-); in the event that a punch pattern is not found then a question mark (?) is provided.
Examples include C-S, ?-A, ?-?. By adding the "_END" suffix to these variables the matching process is reversed -- starts at the end-end.
|
Name |
Type |
Row Type |
Description |
|---|---|---|---|
|
CUSTOM.PUNCH_CODE_WEB |
String |
Part |
Provides matching punch code against provided patterns for the beam web. Returns a question mark when no match is found. |
|
CUSTOM.PUNCH_CODE_TOPFL |
String |
Part |
Provides matching punch code against provided patterns for the beam top flange. Returns a question mark when no match is found. |
|
CUSTOM.PUNCH_CODE_BTMFL |
String |
Part |
Provides matching punch code against provided patterns for the beam bottom flange. Returns a question mark when no match is found. |
|
*Variations: |
|
|
Add "_END" to the end to analyze from the beam end point direction E.g. CUSTOM.PUNCH_CODE_WEB_END, CUSTOM.PUNCH_CODE_TOPFL_END, CUSTOM.PUNCH_CODE_BTMFL_END |
4.3. Punch Code Extra Holes
These variables provide the unmatched holes resulting from the punch code pattern matching. Additional variations of the variables are provided via suffixes that allow for dimensions from the end-end of the beam, for different delimiters between values, and for the formatting of the values (see section 4.4).
|
Name |
Type |
Row Type |
Description |
|---|---|---|---|
|
CUSTOM.PUNCH_EXTRA_WEB |
String |
Part |
Provides running local x dimensions from the start-end for bolt groups that don't match the punch code for the web of the beam. Formatted according to unit settings and space delimited. For variations in numerical formats see section 4.4 below. |
|
CUSTOM.PUNCH_EXTRA_TOPFL |
String |
Part |
Provides running local x dimensions from the start-end for bolt groups that don't match the punch code for the web of the beam. Formatted according to unit settings and space delimited. For variations in numerical formats see section 4.4 below. |
|
CUSTOM.PUNCH_EXTRA_BTMFL |
String |
Part |
Provides running local x dimensions from the start-end for bolt groups that don't match the punch code for the web of the beam. Formatted according to unit settings and space delimited. For variations in numerical formats see section 4.4 below. |
|
*Variations: |
|
|
Add "_A" -> "_U" at the end for formatting string units, see Section 4.4 E.g. CUSTOM.PUNCH_EXTRA_WEB_A |
4.4. Variations
*Variations with running dimensions from the start-end:
| Suffix | Delimiter | Format | Example |
|---|---|---|---|
|
_A |
Comma | ft in frac | 6 1/4",1'-1 1/2" |
|
_B |
Comma | ft decimal | 0.52',1.13' |
|
_C |
Comma | in frac | 6 1/4",13 1/2" |
|
_D |
Comma | in decimal | 6.25",13.50" |
|
_E |
Comma | mm decimal | 158.75,342.9 |
|
_F |
2x space | in frac | 6 1/4" 13 1/2" |
|
_G |
2x space | ft in frac | 6 1/4" 1'-1 1/2" |
|
_H |
1x space | ft decimal | 0.52' 1.13' |
|
_I |
1x space | in decimal | 6.25" 13.50" |
|
_J |
1x space | mm decimal | 158.75 342.9 |
*Additional variations with running dimensions from the end-end:
| Suffix | Delimiter | Format | Example |
|---|---|---|---|
|
_K |
Space | default units | varies |
|
_L |
Comma | ft in frac | 6 1/4",1'-1 1/2" |
|
_M |
Comma | ft decimal | 0.52',1.13' |
|
_N |
Comma | in frac | 6 1/4",13 1/2" |
|
_O |
Comma | in decimal | 6.25",13.50" |
|
_P |
Comma | mm decimal | 158.75,342.9 |
|
_Q |
2x space | in frac | 6 1/4" 13 1/2" |
|
_R |
2x space | ft in frac | 6 1/4" 1'-1 1/2" |
|
_S |
1x space | ft decimal | 0.52' 1.13' |
|
_T |
1x space | in decimal | 6.25" 13.50" |
|
_U |
1x space | mm decimal | 158.75 342.9 |
5. Notes
- Excludes "No Hole" bolt groups from consideration
- Retains the first punch code match unless there are fewer excess punches in subsequent matching rules
- No size checks are made other than if the maximum punch code value exceeds the length of the part
- Any non-comment line that includes the word "stop" ends the reading of DT_PUNCH.SIZ -- all lines after are ignored
- Any non-comment line in DT_PUNCH.SIZ that includes question marks "??" is ignored