メインコンテンツに移動

Release Info Tekla Structures 2026

Tekla Structures 2026
2026
Tekla Structures
Environment
Netherlands

The Tekla Structures 2026 Release Info contains the following topics:

General

Tekla Structures 2026 videos

Tekla Structures 2026 includes many new features and improvements that are explained in this Release Info.

 

Image
RI_2026_032

 

In addition, instructional videos are available for a number of features.

Click here for the videos.

Modified startup roles

When you start Tekla Structures, you select a role in the Tekla Structures - Set up dialog box that you want to use while working in Tekla Structures. The role you choose determines which settings are available in Tekla Structures.

For example, Tekla Structures 2025 includes the Multimaterial Detailer role:

 

Image
RI_2026_037_enu_a

 

In Tekla Structures 2026, this role has been renamed to Multimaterial Detailer Concrete:

 

Image
RI_2026_038_enu

 

In addition, the Multimaterial Detailer Steel and Multimaterial Detailer Timber roles are now available.

When you use the Multimaterial Detailer Concrete role, the focus is on concrete, but steel-related settings are also available, such as steel-related lists.

The Multimaterial Detailer Steel role is the reverse of the Multimaterial Detailer Concrete role, where the focus is on steel, but concrete-related lists/settings are also available.

The Multimaterial Detailer Timber role is a combination of timber and steel, where the focus is on timber, but steel-related lists/settings are also available.

 

No changes have been made to the other roles. If the role you use in Tekla Structures 2025 meets your needs, you can continue using it in Tekla Structures 2026.

Improvements in the Display & filtering command

In Tekla Structures, the side pane includes the Display & filtering command (1), which by default contains several tabs (2):

 

Image
RI_2026_039_enu

 

Assembly hierarchy: For displaying the hierarchy of assemblies, nested assemblies, and super assemblies.

Phases: For displaying different phases in model views.

Name: For displaying the different names of model objects.

Attributes: For displaying the different attributes.

 

Various improvements have been made to the Display & filtering command in Tekla Structures 2026, such as the ability to use spaces in names and finishes and in filters.

 

Tip: Did you know that since Tekla Structures 2025, the Display & filtering command has included the practical Combine with phase filter?

 

Image
RI_2026_059_enu


This allows you to combine options in the Phases tab with options in the Name tab or one of the other options:

 

Image
RI_2026_060_enu


For example, in a Tekla Structures model in which UNP140 profiles appear in multiple phases, you can easily create a combination that only displays the UNP140 profiles that are in phase 2.

Click here for detailed information and an example of the Combine with phase filter option.

 

Click the Help button for detailed information about how the Display & filtering command works.

New profile catalog: Merging groups and profiles added

In Tekla Structures 2026, you have access to a new profile catalog:

 

Image
RI_2026_001_enu

 

The profile catalog has the same look and feel as the Shape and Rebar catalog in Tekla Structures, making the catalog structure more uniform. The clear structure provides better search and filter options and makes it easier to add, modify, and structure profiles.

If you added profiles to the profile catalog (the file profdb.bin) in previous versions of Tekla Structures and you copy this profile catalog to Tekla Structures 2026, you will still have all the profiles from previous versions of Tekla Structures (1) and you can search for all profiles (2):
 

Image
RI_2026_061_enu

 

As a result of the new layout, all profiles that you added yourself in a previous version are not placed in a group but in the Ungrouped group:

 

Image
RI_2026_062_enu

 

All profiles supplied by Construsoft are already divided into groups by default.

To divide your own profiles into groups again, do the following:

Click the New group > New group button:
 

Image
RI_2026_063_enu

 

and enter a desired name for the group in the New group name dialog box:

 

Image
RI_2026_064_enu

 

Click the Create button to add the group:

 

Image
RI_2026_065_enu

 

Now find the profiles you want to have in the relevant group:

 

Image
RI_2026_066_enu

 

Select the filtered profiles with the Select all button and drag them to the relevant folder:

 

Image
RI_2026_067_enu

 

If necessary, repeat the steps for the other profiles you want to divide into groups and then click the Save button:

 

Image
RI_2026_068_enu

 

The group(s) is/are now saved in the model folder with the name

ProfileCatalog.Groups.User.<username.xml

in the subfolders:

..\profil\Profiles

If you want to use the new group layout in a model template, in other models, or in all models, copy the subfolders, including the *.xml file, to the model template, another model, or your TS folder.

If you want to share your new group layout with colleagues in a Tekla Model Sharing model, for example, click the Share Groups button.

In the dialog box that appears, click the Share Groups button and then click the OK button.

The group(s) is now saved in the model folder with the name

ProfileCatalog.Groups.xml

in the subfolders:

..\profil\Profiles

If you save this file with the subfolders in model templates, other models, or in your company's TS folder, the groups will be available to everyone.

Please note: Nothing has been changed in the profile catalog itself (the profdb.bin file), so you do not need to do anything else with it.

 

Click here and here for detailed information about the improvements in the new profile catalog and how to customize the new profile catalog.

 

In addition, the following parametric profiles have been added to the new profile catalog:

 

REDUCER
Image
RI_2026_004a
ROUROU
Image
RI_2026_005a
ROUREC
Image
RI_2026_006a
CAP_A
Image
RI_2026_007a
CAP_B
Image
RI_2026_008a

 

The profile definitions are stored in the profitab.inp file in the folder

C:\TeklaStructures\2026.0\Environments\ConstrusoftEuropean\General\Profil

 

Custom modifications

If you made changes to the profitab.inp file in previous Tekla Structures versions and possibly stored the file in a central folder (such as the TS folder or in the cloud), you can, if desired, add the lines that describe the parametric profiles from the original profitab.inp file (stored in the folder mentioned above) to your own profitab.inp file:

 

Image
RI_2026_009

Material catalog updated

In Tekla Structures 2026 (and also in Tekla Structures 2025 Service Pack 7), the material grade CorTen_A has been added to the material catalog:

 

Image
RI_2026_002_enu

 

COR-TEN A is a type of steel that is intentionally allowed to rust in a controlled way (warm brown-orange color).

 

Custom modifications

You may have modified the material catalog (the matdb.bin file) in your previous Tekla Structures version.

To ensure that the CorTen_A material grade is available in your material catalog, you can export the CorTen_A material grade from the material catalog provided by Construsoft (stored in the folder C:\TeklaStructures\2026.0\Environments\ConstrusoftEuropean\General\Profil):

 

Image
RI_2026_003_enu

 

and import it into your own material catalog:

 

Image
RI_2026_004_enu

 

Click here for detailed information about merging the material catalog.

Localization: Updating custom settings/files

General information about localization and migration of the Construsoft tools

When you start Tekla Structures 2026 for the first time after installation, the Tekla Structures Migration Wizard dialog box appears automatically:

 

Image
RI_2026_005_enu

 

You can use the Migration Wizard to copy various personal settings and extensions (tools/plug-ins) to the new Tekla Structures version.

However, we strongly advise against doing this because extensions may have been renewed or updated, and by migrating them you may miss these developments.

The Construsoft tools from Tekla Structures 2025 or earlier are not compatible with Tekla Structures 2026 and must therefore not be migrated when using the Migration Wizard:

 

Image
RI_2026_006_enu

 

If you later decide to copy settings after all (excluding the Construsoft tools), you can manually start the Migration Wizard by double-clicking the file MigrationWizard.exe in the folder

..:\TeklaStructures\2026.0\bin\applications\Tekla\Migrations.

To start Tekla Structures, click the Skip Copying button.

To obtain the missing tools (the tools included in the ConstrusoftEuropean environment are added during installation of the Construsoft developments), you can download and install them from Trimble Warehouse.

Updating model templates

If you have your own model templates, update them to ensure they can be used without issues in Tekla Structures 2026.
 
Click here for the (general) step-by-step instructions.

The customized ribbon and shortcuts

After installing Tekla Structures 2026, you can copy your customized ribbon and shortcuts from an older Tekla Structures version to Tekla Structures 2026.

Copying the ribbon

In Tekla Structures 2026, you have the option to copy your customized ribbon from an earlier Tekla Structures version to Tekla Structures 2026.
 

NOTE: If you do this, new command buttons introduced in Tekla Structures 2026 will not be included.

You may also choose to first compare the “old” ribbon with the new “default” ribbon in Tekla Structures 2026 via File > Settings > Ribbon > Compare in both the Model and Drawing Editor.

You will then see the differences between your customized ribbon and the default ribbon of Tekla Structures 2026.

You can then decide to add the missing command buttons or start using the new default ribbon.

To copy the customized ribbon, follow these steps:

1. In Windows Explorer (depending on the Tekla Structures version), go to the folder
 
C:\Users\<user>\AppData\Local\Trimble\TeklaStructures\<older version>\UI\Ribbons\
 
or the folder

C:\Users\<user>\AppData\Local\Trimble\Tekla Structures\<older version>\UI\Ribbons\

(If the folder is not visible in Windows Explorer, click the three-dot menu at the top and select Options. In the dialog box that appears, click the View tab and enable the checkbox for Show hidden files and folders).

 
2. The *.xml file albl_up_<license>--main_menu.xml contains the customized ribbon.
3. Place this *.xml file in the folder C:\Users\<user>\AppData\Local\Trimble\Tekla Structures\2026.0\UI\Ribbons.

Note that the ribbon file name is determined by the Tekla Structures configuration you are using. For example, for the Steel Detailing configuration, the file name albl_up_Steel_Detailing--main_menu.xml is used.

Since three new configurations have been available since Tekla Structures 2021, the following table shows the available configurations and their file names:

 

Image
RI_2026_036_enu

 

* New since Tekla Structures 2021. These options are only available if you have a subscription.

Click here for more detailed instructions on copying the ribbon.

Copying shortcuts

Copy shortcuts from an earlier Tekla Structures version to Tekla Structures 2026 as follows:

1. In an earlier Tekla Structures version, go to File > Settings > Keyboard shortcuts.

2. Click the Export button and save the *.xml file in the desired location with the desired name.

3. In Tekla Structures 2026, go to File > Settings > Keyboard shortcuts.

4. Click the Import button, select the *.xml file, and click Open. The shortcuts will now be imported.

You can also copy the exported *.xml file to another PC to import it there into Tekla Structures 2026.

The customized Applications & components catalog

In Tekla Structures, you have access to the Applications & components catalog and the ability to customize it.

This may include creating your own groups, adding subgroups, or adjusting the order of groups.

 

Image
RI_2026_007_enu

 

In Tekla Structures, the Applications & components catalog (the groups from Concrete through Timber) is stored in separate *.xml files in the folder

..:\TeklaStructures\2026.0\Environments\ConstrusoftEuropean\General\ComponentSettings:
 

Image
RI_2025_053

 

Because the groups are stored separately, the Applications and Components database can easily be maintained per group and groups can be exchanged easily. For example, if you have added your own group to the Applications and Components database, you can publish (export) this group to a *.xml file:

 

Image
RI_2026_040_enu

 

...and save it in your TS folder or share it with colleagues or third parties. (They store the *.xml file in their own TS folder.)

 

In Tekla Structures 2026, the Engineering group (file CSE_ComponentCatalog.ac.xml) has been updated and the components Design group numbering (see also chapter Tools/plug-ins > Design Group Numbering (ML002)) and Sequence Tool (ML013) have been added:

 

Image
RI_2026_008_enu

 

In addition, various tags have been added to the Design group numbering component that can be used in search queries:

 

Image
RI_2026_009_enu

 

Click here for more detailed information about maintaining the Applications and Components database.


Release Notes for administrators

This Construsoft Release Info highlights various settings and files to ensure that you can start working quickly in Tekla Structures 2026.

In addition to this Release Info, the so-called Release Notes for administrators from Tekla are also available. These Release Notes provide even more information about changes that may be of interest to you.

Review this information as a Tekla Structures user or ask your system administrator to review it to see what else may require attention.

Interoperability

IFC export: id_IFC_check report updated

In Tekla Structures, you have the option to export a Tekla Structures model (or part of it) to an IFC file.

Click here for detailed information about exporting to an IFC file.

 

Before exporting a Tekla Structures model or parts of a model to an IFC file, always first check whether the objects you want to export have the correct IFC entity and Subtype (IFC4).

This prevents objects from not being exported to IFC because the IFC entity of the relevant objects is set to None or Auto instead of a valid entity (IfcBeam through IfcWindow):

 

Image
RI_2026_010_enu

 

To quickly check this in a model, you can use the id_IFC_check report:

 

Image
RI_2026_011_enu

 

This report only shows objects for which the IFC entity is set to None or Auto in the IFC entity column:

 

Image
RI_2026_012_enu

 

The report has been updated in Tekla Structures 2026, and the IFC entities IfcCovering, IfcCurtainWall, IfcRampFlight, and IfcStairFlight are now included in the report conditions:

 

Image
RI_2026_013_enu

 

Image
RI_2026_014_enu

Modeling

New Excel reports available

In Tekla Structures 2026, you have a new way to create professional-looking Excel reports (.xlsx files) directly from Tekla Structures. Various changes and improvements have been made in the Template Editor and in Tekla Structures to enable this.

A number of Excel reports are available by default.

 

Image
RI_2026_015_enu

 

Image
RI_2026_056_enu

 

Click here for detailed information about the new Excel reports.

Modified report PDF-bending-schedule_shape_per_cast_unit.pdf

In Tekla Structures 2026, the report PDF-bending-schedule_shape_per_cast_unit.pdf has been modified so that the total reinforcement weight is now displayed correctly.

Previous Tekla Structures versions:

 

Image
RI_2026_054_enu_b

 

Tekla Structures 2026: 

 

Image
RI_2026_055_enu_b

Size of default views adjusted

When working in Tekla Structures, you can create so-called “default views” from a system component.

To do this, select the component symbol, right-click, and select the command Create view > Default views of component:

 

Image
RI_2026_016_enu

 

Tekla Structures creates four views so that the component parts can be clearly seen from different perspectives:

 

Image
RI_2026_048a

 

This allows you, for example, to properly verify the dimensions:

 

Image
RI_2026_049

 

To ensure that these default views correctly fill the screen as a result of the new Model views side pane, the sizes of these default views have been adjusted in Tekla Structures 2026.

In Tekla Structures, you can use the advanced option XS_BASICVIEW_WIDTH to define the width and the advanced option XS_BASICVIEW_HEIGHT to define the height of default views. Enter the number of pixels for these advanced options.

In earlier Tekla Structures versions, the values were set to 820 and 395.

In Tekla Structures 2026, the values are set to 600 and 375.

 

Tip: To quickly close the four basic views, use the keyboard shortcut Ctrl + F4.

System components

Opening in wall (40)

In Tekla Structures, you have system component Opening in wall (40), which allows you to generate multiple openings, optionally combined with transportation profiles, grip profiles, borders, embeds, insulation and girders.

 

Image
RI_2026_017_enu

 

The system component includes various improvements and new options.

Sometimes some braced girders around cut-outs are not created. Now some tolerance issues has been fixed which was preventing the creation of girders.

It is now possible to specify class property of the openings on the Opening 1 tab:

 

Image
RI_2026_041_enu

 

The option Ignore recesses on tab page Insulation has been changed to Ignore cutout classes and names so now user can specify the cuts which should be ignored based on name or class instead of automatic detection of recess. 

It is now possible to specify horizontal areas where insulation will not be created and you can now specify the minimal dimensions of the insulation which should be created:

 

Image
RI_2026_042_enu

 

Previously, option to ignore cutouts by classes or names for insulation was not ignoring cutouts created by component itself. This has been fixed now.

A functionality has been added to prevent a crash of the component.

 

Click the Help button in the system component for detailed information about how the Opening in wall (40) system component works.

Wood wall (57)

In Tekla Structures, you have system component Wood wall (57), which allows you to create wooden wall elements based on studs, beams and plates. This element can have a maximum of 6 openings.

 

Image
RI_2026_018

 

The system component now includes several improvements.

For example, the settings on the Edge details tab are now applied in all cases:

 

Image
RI_2026_043_enu

 

In addition, the edge details are now correctly created when the top beam of the element is sloped or has a roof shape.

 

Click the Help button in the system component for detailed information about how the Wood wall (57) system component works.

Rebar in beam (90)

In Tekla Structures, you have system component Rebar in beam (90), which allows you to create full adaptive reinforcement in concrete beams and columns with complex shapes. 

 

Image
RI_2026_020_enu

 

The system component includes improvements and new options.

The option Ignore cutout classes or names works now also for stirrups which are created by scan polygon point options. 

In some cases, the component crashed. This has now been fixed.

It is now possible to specify the same cover thickness for all longitudinal rebars on tab page Advanced:

 

Image
RI_2026_044_enu

 

Previously, when longitudinal rebars were specified by distance list some rebars were created in incorrect position. This has been fixed now.

It is now possible to specify custom hook angles for stirrups:

 

Image
RI_2026_045_enu

 

It is now possible to specify which extra stirrups groups should be used on each Stirrups tab page:

 

Image
RI_2026_046_enu

 

It is now possible to select new spacing types for stirrups: By exact spacing value with flexible first space and By exact spacing value with flexible last space:

 

Image
RI_2026_047_enu

 

Click the Help button in the system component for detailed information about how the Rebar in beam (90) system component works.

Border rebar (92)

In Tekla Structures, you have system component Border rebar (92), which allows you to create pins (U-bars), stirrups and edge bars on all edges of a concrete slab or a concrete panel.

 

Image
RI_2026_021_enu

 

The system component includes improvements and new options.

Previously, the component could respond somewhat slower in larger models. This has now been fixed.

Pins and Stirrups have now new creation method how to calculate spacings with common options in rebar groups:

 

Image
RI_2026_048_enu

 

A new option is added to have separated bottom and top cover thickness for stirrups:

 

Image
RI_2026_049_enu

 

Click the Help button in the system component for detailed information about how the Border rebar (92) system component works.

Bolts in a part (1006)

In Tekla Structures, you have system component Bolts in a part (1006), which allows you to position a bolt pattern in a profile. Instead of bolts also studs or profiles can be positioned.

 

Image
RI_2026_022_enu

 

The system component has been expanded and now includes new options for creating tapped holes and for defining the type and direction of slotted holes:

 

Image
RI_2026_023_enu

 

Click the Help button in the system component for detailed information about how the Bolts in a part (1006) system component works.

Footplate (1029)

In Tekla Structures, you have system component Footplate (1029), which allows you to place base plates under columns.

 

Image
RI_2026_024_enu

 

The system component includes various improvements.

The calculation of the length of different anchor types has now been adjusted.

Anchor type 5 in the model:

 

Image
RI_2026_055

 

In the single-part drawing:

 

Image
RI_2026_050_enu_a

 

Anchor type 2 in the model:

 

Image
RI_2026_057

 

In the single-part drawing:

 

Image
RI_2026_051_enu

 

Anchor type 6 in the model:

 

Image
RI_2026_059

 

In the single-part drawing:

 

Image
RI_2026_052_enu

 

Anchor type 3 in the model:

 

Image
RI_2026_061

 

In the single-part drawing:

 

Image
RI_2026_053_enu

 

In addition, several images in the system component dialog box have been updated for clarity, and countersunk holes in fitting plates sometimes had an incorrect bolt standard. This has now been corrected.

 

Custom settings

If you created settings for the system component Footplate (1029) in an earlier version of Tekla Structures, check whether the relevant countersunk holes have the correct bolt standard. Adjust the settings if necessary, save them again, and then copy them to your central folder (such as the TS folder or the cloud). This also applies to reports and templates.

Click the Help button in the system component for detailed information about how the Footplate (1029) system component works.

Multiple stiffeners (1064)

Tekla Structures includes system component Multiple stiffeners (1064), which allows you to create multiple stiffeners.

 

Image
RI_2026_057_enu


The system component now has a new Holes tab with options for creating sink holes and setting their position:

 

Image
RI_2026_058_enu


These new options are currently only available in system component Multiple stiffeners (1064), but if they are well received by users, they will also be added to other commonly used steel-related system components.

Custom settings

If you created settings for the system component Multiple stiffeners (1064) in an earlier version of Tekla Structures, check if you want to use the new option for sink holes. Adjust the settings if necessary, save them again, and then copy them to your central folder (such as the TS folder or the cloud).

Click the Help button in the system component for detailed information about how the Multiple stiffeners (1064) system component works.

Template Editor

New Template Editor version

In Tekla Structures 2026, you have a new version of the Template Editor:

 

Image
RI_2026_025_enu

 

All available templates and reports from Construsoft have been saved in this new version so that they are compatible with Tekla Structures 2026.

 

Custom templates and reports

If you have self-created or customized templates and reports, you can choose to save them once in the new Template Editor version. This is not strictly necessary; if you do not update the templates and reports to the new Template Editor version, they will continue to function as they did in previous versions.

To save your templates and reports once in the new Template Editor version, follow these steps:

1. In Tekla Structures 2026, open the new Template Editor (via File > Editors > Template editor).

2. Open a self-created or customized template or report. The following message appears:

 

Image
RI_2026_026_enu

 

3. Double-click in the template or report. The Template Properties dialog box opens.

4. Click the OK button. The dialog box closes.

5. Go to File > Save (or use the shortcut Ctrl + S). The following message appears:

 

Image
RI_2026_027_enu_a

 

Click the Update button. The relevant template or report has now been updated.

Tools/plug-ins

Design Group Numbering (ML002)

In earlier Tekla Structures versions, if you worked with a configuration where you could not (comparatively) number parts (Engineering or Construction Modeling, Graphite or Carbon), for example for numbering pile plans or cladding, you could use the Design Group Numbering (ML002) tool.

 

Image
RI_2025_093

 

Image
RI_2026_029_enu

 

In Tekla Structures 2026, the Design Group Numbering (ML002) tool has been adopted by Tekla and is now available under the name Design Group Numbering in the Applications & components catalog:

 

Image
RI_2026_030_enu

 

Image
RI_2026_031_enu

 

Custom settings

If you created custom settings (*.tsdgn files) in earlier Tekla Structures versions, check these settings and adjust them if necessary so that you can use them without issues in Tekla Structures 2026.

 

Click here for detailed information about how the system component works.

NC files

NC files: Numbers in the header of NC files

When generating NC files in Tekla Structures, you can create them for all parts or for the selected parts:

 

Image
RI_2026_032_enu

 

All parts

This creates NC files for all parts in the model.

 

Selected parts

This creates NC files for the selected parts in the model. The number of parts included in the header of the NC file can be controlled using the advanced option XS_DSTV_NUMBER_OF_PARTS_BY_SELECTION.

 

In earlier Tekla Structures versions, the advanced option was set to FALSE. When generating NC files, the number of parts in the header of the NC file corresponded to the total number of parts in the Tekla Structures model.

In the Tekla Structures model, one beam is selected, but there are four beams in total in the model:

 

Image
RI_2026_026

 

Image
RI_2026_033_enu

 

In the NC file:

 

Image
RI_2026_034_enu

 

In Tekla Structures 2026, the advanced option is set to TRUE by default in the file env_ConstrusoftEuropean.ini in the folder

C:\TeklaStructures\2026.0\Environments\ConstrusoftEuropean.

When you now create NC files and have selected the Selected parts option in the NC Files dialog box, the value in the header of the NC file corresponds to the number of selected parts.

 

In the NC file:

 

Image
RI_2026_035_enu

 

This prevents the number of parts in the header of the NC files from being too high, which could otherwise result in too many parts being produced.

 

Click here for more information about the advanced option XS_DSTV_NUMBER_OF_PARTS_BY_SELECTION.

Click here for an instructional video about defining the number of parts in the header of NC files.

送信

Table of Contents