Albion Eaves Beam to Stanchion (104)
Not version-specific
Tekla Structures
Environment
Not environment-specific
The Albion Eaves Beam to Stanchion connection will define a fixing bracket according to the set of parameters specified with either standard or non-standard stooling dimensions. The joint will define all bolts and welds required, and where appropriate will also fit the ends of the eaves beams to leave the correct end gap.
Before and after
Image
Image
Notes
- Any modification of the selected parts will cause this joint to be updated.
- When connection is applied the default connecting profile is always an L100*62*8, this can be overwritten in the Parts tab.
Selection order example
- Column
- Eaves Beam
- Eaves Beam
- Click middle mouse button
Image
See also
Albion cold rolled - Important information
Albion Eaves Beam to Stanchion (104) - Parts tab
Albion Eaves Beam to Stanchion (104) - Parameters tab
Albion Eaves Beam to Stanchion (104) - Bolts tab