주요 콘텐츠로 건너뛰기

SIA 262 (2025) in Tekla Structures

Tekla Structures - Not version-specific sia sia262
Not version-specific
Tekla Structures
Environment
Switzerland

General information

SIA 262 (2025) has been in force since November 1, 2025. It introduces significant changes to working with reinforcement and, as a result, to reinforcement design with Tekla. Some relevant changes are:

  • New calculation of anchorage lengths; the rule of thumb 50 × Ø is no longer generally valid.
  • Bends according to d2 no longer exist. There are now only standard bends according to d1 or d3. As a result, the bending roll diameters and bending radii for bends according to d1/d3 have also been changed.
  • New calculation of hook lengths. The end hook lengths specified in the iron list figure now correspond to the “leg length” of the hook, no longer to the end hook allowance. Please note that the end hook allowance is still relevant for calculating the developed length. In the image, the specification on the figure list of the iron list now corresponds to dimension “B,” but dimension “X” counts for the developed length.
  • Image
    Endhaken SIA262


Due to the significantly higher complexity, we recommend using a digital reinforcement slider, such as: Bewehrungsschieber - Bewehrungstechnik.

Image
icon_warning.png

Please note that you can no longer derive the “unwound length [m]” from the sum of the lengths in the figure list as you could previously. Using this figure as an example, item 4, ø12:

  • Sum of all lengths according to the figure: (10+195+95+195+10)cm = 5.05m
  • For ø12, hook length B=100mm, end hook allowance X=~120mm = +~2cm per end hook.
  • Effective unwound length: (12+195+95+195+12)cm=5.09m. 
Image
Eisenliste Schweiz Längenberechnung SIA262

Technical implications (relevant for administrators)

The new standard affects various settings and files in Tekla. If you have customized any of these in your company folder, you should check and adjust them:

  • Rebar catalog: All reinforcement bars in the catalog must be updated to the new standard. This applies in particular to bending radii and hook definitions. If you have made your own adjustments, we recommend setting the code to SIA262(2025) for clarity.
  • Rebar shape manager: All calculations of bend shapes with end hooks must be updated so that dimension B is used for the figures and dimension X is used for calculating the developed length in the list.
  • Reinforcement settings for drawings: From TS2025 SP7 onwards, there are additional setting options that affect the graphics of the figures in the rebar list. We recommend using the file stored in the Swiss environment. If you absolutely must make adjustments, you should use the file in the Swiss environment as a new basis for your adjustments. You can find the file in the Swiss environment under "\Switzerland\General\System\rebar_config.inp".
  • New rebar list: The Swiss rebar list has also been adjusted and updated as a result of these changes. The Swiss rebar list now shows in the table header on page 2 whether SIA262 (2025) or the old SIA standard was used for the reinforcement
Image
Eisenliste Schweiz Hinweis Norm SIA262

SIA 262 (2013)/(2025) in Tekla Structures 2025 (or before)

If you need to continue using the SIA 262 (2013) standard, you do not need to take any action in Tekla Structures 2025.

Before Tekla Structures 2025 Service Pack 7

If you need to use the new SIA 262 (2025) in a lower version and cannot update to Tekla Structures 2025 Service Pack 7 or newer, contact support for assistance.

From Tekla Structures 2025 Service Pack 7 onwards

Make sure that you have also installed the latest Swiss environment when installing Service Pack 7.

This service pack contains relevant translations and settings required for the SIA 262 (2025) standard.

If you want to create reinforcement according to SIA 262 (2025) in a specific model, install the necessary content directly into the corresponding Tekla model via Tekla Warehouse. To do this, select the SIA 262 (2025) version.

SIA 262 (2013)/(2025) from Tekla Structures 2026 onwards

Starting with Tekla Structures 2026, SIA 262 (2025) will be used as the default standard. This means that all reinforcement in models opened in Tekla Structures 2026 will be automatically calculated using this standard, unless you explicitly choose to do otherwise (see next chapter).

If you want to edit a model with the old SIA 262 (2013) standard in Tekla Structures 2026, install the necessary content directly into the corresponding Tekla model via Tekla Warehouse. To do this, select the SIA 262 (2013) version.

 

Please note that models created in Tekla Structures versions prior to 2026 and subsequently opened/edited in Tekla Structures 2026 or later will be automatically converted to the new standard.

To prevent this and to enforce the use of a specific SIA standard (2013 or 2025) in the model, you can install the relevant content from Tekla Warehouse into the model as described in the chapter above.

Please note that the following factors, among others, have an influence on the display of the reinforcement:

Settings:

  • Bend radius: Please note that the bend radius is fixed in Tekla. When updating the reinforcement catalogs to the new SIA 262 (2025) standard, these are not automatically adjusted. You can tell whether you are using a standard bending radius (d1/d3) by checking whether the number is in square brackets []. If not, it is a user-defined bending radius:
  • Image
    Standard Biegeradien
  • The hook lengths of the end hooks are read from the reinforcement catalog and are adjusted when the model is opened if the catalog is changed. “User-defined end hooks” are an exception.
     

Files:

  • rebar_database.inp: This file contains the reinforcement catalogs. If this file is present in the model folder, these catalogs will always be used for reinforcement, not those from the Swiss environment.
  • RebarShapeRules.xml: This file contains the calculations for bending shapes. Among other things, it influences the calculation of the developed length. This file should always match the reinforcement catalogs in order to meet the requirements of a specific SIA standard.
  • rebar_config.inp: Typically, this file is not in Tekla model folders unless it has been copied manually. The file defines how reinforcement is displayed on drawings or in the figure graphics on the rebar list.
  • .Eisenliste_Schweiz.pdf.rpt: Or similar Tekla lists define how the rebar list is printed as a PDF. Your rebar list template in the model or company folder must be updated again in line with the new standard and re-adopted and adapted by the Swiss environment.
전송