Overslaan en naar de inhoud gaan

How is the Tension Flange Weld checked?

Tekla Connection Designer 18 tension weld
18
Tekla Connection Designer
Environment
British Standard

Example

Design Data
Flange width; Bb = 318.4 mm
Flange thickness; Tb = 37.7 mm
Web thickness; tb = 23 mm
Beam design strength; py = 345 N/mm2
Endplate width; Bp = 320 mm
Weld; s = 10 mm
Weld strength; pw = 220 N/mm2
Tension Force
Fftw_a = Bb x Tb x py = 4141.270 kN
For flush end plate - Total tension force in the top two bolt rows
For extended end plate - Total tension force in the top two bolt rows+ bolt rows in extension
tension force in row 1; R1 = 274.4 kN
tension force in row 2; R2 = 222.9 kN
Fftw_b = R1 + R2 = 497.300 kN
Tension Force; Fftw = min(Fftw_a, Fftw_b) = 497.300 kN
Tension Capacity
Pftw1 = 1.25 x ( 2 x Bb - tb + 2 x Tb ) x 0.7 x s x pw = 1326.710 kN
Pftw2 = 1.25 x ( 2 x Bb - 4 x s - tb ) x 0.7 x s x pw = 1104.565 kN
Tension Capacity; Pftw = if(Bp < Bb + 2 x s, Pftw2 ,Pftw1 ) = 1104.565 kN
Utilisation; Fftw / Pftw = 0.450
Indienen