Duggans Cold Rolled Sleeved - Parameters tab
Not version-specific
Tekla Structures
Environment
Not environment-specific
Use the Parameters tab in the Duggan Steel Cold Rolled Sleeved Properties panel to control how the sleeve is defined within Tekla Structures.
Image
| Option | Description | Default | Other |
|---|---|---|---|
| Group | This sets the class that all parts will be included in. | The default setting is 99. | |
| Secondary end gap | If two purlins are selected in the application of the joint then this value specifies the gap between the two purlins. Each purlin will be cut back half the distance from the centre of the fixing bracket. | The default setting cuts each purlin back 5mm from the center line. |
Image
Image
|
| Cleat Finish | This specifies the finish of the cleat. Note that a galvanised finish will be used if the string entered here is prefixed with the characters “GALV”. | The default is set to Empty. | |
| Sleeve (No, Yes) | This allows the user to select if the connection has a sleeve or not. A sleeve can be selected to allow for future extensions at gable ends. | The default is set to No. | |
| Force sleeve holes (No, Yes) | This allows the user to force holes to be placed in the purlins corresponding to the sleeve hole positions when there is no sleeve. This will be done only if this option is set to Yes, otherwise when set to No these holes will be omitted. | The default is set to No. | |
| Stays (No, Both, Left Right) | This allows the user to define whether they want rafter stays or not, and to place them on only one side of the rafter/stanchion if required. You may wish to include both rafter stays at an overhang in order to allow for future extensions. Left and right are specified from the cleat side as shown in image. | The default is set to No, rafter stays are turned off. |
Image
|
| Force stay holes (No, Yes) | This allows the user to force holes to be placed in the purlins corresponding to the stay hole positions when there is no stay. This will be done only if this option is set to Yes, otherwise when set to No these holes will be omitted. | The default is set to No. | |
| Cleat (Bolted, Welded) | This specifies whether the cleat is welded or bolted to the rafter. If the cleat profile is not explicitly given in the parts dialogue the standard profile will be used from the data files. | The default is set to Bolted. | |
| Siffened CLeat (No, Yes) | This is a simple field to indicate if the stiffener should be defined or not. | The default is set to No. | |
| Stay plate Width | This sets the width of the plate to the rafter / stanchion used with the rafter stays. | This value will come from the data files. |
Image
|
| Stay plate Height | This sets the length of the plate to the rafter / stanchion used with the rafter stays. | This value will come from the data files. |
Image
|
| Stay plate Thickness | This sets the thickness of the plate to the rafter / stanchion used with the rafter stays. | This value will come from the data files. | |
| Gable Overhang | This specifies the overhang dimension for a gable end only. The dimension is measured from the centre of the cleat. | The default setting is no extension. |
Image
|
| Stay bolt delta X | This specifies the offset position of the bolt from the default position along the purlin length, positive values move the bolt towards the column centre. | This value will come from the data files. |
Image
|
| Stay bolt delta Y | This specifies the offset position of the bolt from the default position perpendicular to the purlin, positive values move the bolt towards the sheeting face. | This value will come from the data files. |
Image
|
| Stay Delta X | This specifies the offset position of the end of the stay where it connects to the purlin. Positive values move the end location away from the column centre. | This value will come from the data files. |
Image
|
| Cleat Height | This defines the full length of the cleat. For standard or non-standard cleats, it need only be given where the length is not to be the same as that derived from the standard hole positions. For a connection to a stanchion web, the cleat may be automatically extended to preserve the top end distance for the holes. Some cleats, e.g. angles, cannot be extended in this way, and so an alternative cleat must be used by specifying the cleat profile in the parts tab. | This value will come from the data files. |
Image
|
See also
Duggans cold rolled - Important informationDuggans Cold Rolled Sleeved
Duggans Cold Rolled Sleeved - Parts tab