You can create meshed masonry walls in level, frame, or structure views. For detailed information on creating masonry walls, see the following instructions.
Material type
The Grade lists all the available Masonry materials in the Materials database under the current regional code.
If the grade you want to use is not listed, you can open the Materials dialog and add the grade to the database.
Geometric rules
- Masonry walls must be rectangular in a vertical plane.
- Openings are permitted in masonry walls.
- The alignment and offsets in the wall properties are not structurally significant as they have no affect on the solver elements that are formed in the solver model.
- Masonry meshed walls cannot be included in cores.
Sub-division of meshed walls
Each wall object is split into separate panels only at those construction levels where an element or slab attaches to the wall. At the levels where the wall has been split, wall beam elements are also inserted.
Create masonry walls in a level view
Create masonry walls in a frame or structure view
Masonry wall properties
Select one or more masonry wall and then use the Properties window to view and modify their properties.
| General | |
|---|---|
| Name | The automatically generated name. |
| User Name | Can be used to override the automatically generated name if required. |
| Top Level | Specifies the top level for the wall. |
| Base Level | Specifies the bottom level for the wall. |
| Wall Type |
Meshed Shear Wall Note: For
masonry walls the wall type can only be a meshed shear
wall.
|
| AutomaticGenerate Support |
Cleared - a support will only be created if the Generate support property is selected. Selected - a support will only be created if no members/slabs capable of providing support exist under the wall. |
| Generate support |
Cleared - no support is created under the wall. Selected - a support is created under the wall. Note: When a
support is created, a line support is formed under a
meshed wall.
Note: When a
support is created, its degrees of freedom are as
specified in the ‘Wall support’ area of the wall
properties.
|
|
KLL (Head Code ACI/AISC) |
Specify the KLL factor in accordance with Table 4-2 in ASCE 7-05/ASCE 7-10. |
| Plane | Indicates the grid along which the wall is placed. |
| All panels | |
|---|---|
| Grade | The masonry grades that are available here are set from the Materials button on the Home ribbon. |
| Thickness |
The actual thickness of the wall (not nominal). |
| Grout |
|
| Grout spacing | |
| Alignment |
Alignment of the wall:
|
| Alignment offset | When the alignment is set to User it can be adjusted by specifying an exact offset. |
| End 1 extension |
The amount the wall is extended or trimmed back from end 1. A positive extension extends the wall length beyond its insertion point. A negative extension trims the wall back from the insertion point. Note:
End 1 and End 2 are identified by switching on Walls > Direction in Scene Content. They are assigned according to the two points clicked on when the wall is created as follows. If the two points are at the same elevation - End 1 is at the first point clicked. If the points at different elevations - End 1 is at the lowest of the two points. |
| End 2 extension |
The amount the wall is extended or trimmed back from end 2. A positive extension extends the wall length beyond its insertion point. A negative extension trims the wall back from the insertion point. |
| Releases | |
|
Minor Top, Minor Bottom |
Fixed Pinned Continuous (incoming members pinned) For further details, see: Wall releases |
|
Edge 1, Edge 1 |
Fixed Pinned Continuous (incoming members pinned) For further details, see: Wall releases |
| Live Load reduction [ACI/AISC], Imposed Load reduction [Other codes] | |
|
Override calculated value |
This option allows the user to specify their own percentage of load reduction to cater for situations where the automatically calculated value is inappropriate. |
| Analysis & design control | |
| Orthotropic | By default, the wall panels are treated as having isotropic
material properties. Selecting this option allows assigning
orthotropic material properties. For further details, see: Orthotropic walls |
| Calculation |
Only
available when the Orthotropic option has been selected.
|
|
X factor - along the length of the wall. Y factor - along the height of the wall. |
These are only available when the Apply X and Y factors Calculation option has been selected. Applies stiffness modification factors in the local X and Y directions |
| Bending axis adjustment, Ey |
This is only available when the Apply section adjustment factors Calculation option has been selected. Allows you to select the primary bending axis, (Major or Minor) to be used in orthotropic property calculations. |
| Ex, Ey, Gxy, Gxz | Gyz, 𝜈x, and 𝜈y |
Material properties, such as Young’s moduli, shear moduli, and the Poisson’s ratio can be manually set using these fields. They are only editable for Orthotropic walls when the No calculation Calculation option is selected (except 𝜈y, which remains read-only). They are not initially displayed when the Apply section adjustment factors Calculation option has been selected, but are populated once the analysis is complete. Note: No
distinction is made between Gxz and Gyz out-of-plane shear
moduli.
|
| Apply modification factors |
By default, (unless the Orthotropic option has been selected), the modification factors specified in Analysis settings are applied. When this option is cleared the modification factors are not applied. See also: Use of modification factors |
| Assume cracked |
Assuming masonry wall sections are cracked has a direct affect on the analysis; smaller modification factors are applied to cracked sections causing an increase in deflection. Indirectly the design can also be affected because the sway/drift sensitivity calculations are also influenced by this assumption. See: Cracked, partially cracked, and uncracked concrete members The Assume cracked option is not available when the Orthotropic option has been selected. |
| Sway and drift checks | |
| Drift/Seismic drift checks and consider for seismic torsion |
By default all stacks of all walls are taken into account in the calculation to determine the sway sensitivity of the building. The results of this calculation being accessed from the Review toolbar. This parameter provides a facility to exclude particular wall panels from these calculations to avoid spurious results associated with very small panel lengths. You can either clear the checkbox located under ‘All Panels’ to exclude the entire wall, or you can exclude a particular panel by clearing the checkbox located under that panel only. |
| Wind drift check, Wind drift ratio |
Wind drift is automatically checked against the specified limiting ratio, (which can be set differently for different columns). The results of this calculation are accessed from the Review toolbar. If you don’t want this check to be performed you can either clear the checkbox located under ‘All Panels’ to exclude the entire wall, or you can exclude a particular stack by clearing the checkbox located under that panel only. |
| Slenderness | |
|
Major / Minor |
Braced Bracing Note: The
bracing and effective length properties of a masonry
wall are taken into account when calculating it's
effective length, in the same way they are for a
reinforced concrete wall (see: Effective length calculations (column and wall: ACI 318). The
calculated values are then passed on to Tedds to be used
in the design of the wall, where applicable.
|
|
Major / Minor effective length factor |
Calculated User input value |
| Stiffness | |
| Use slab for calculation (upper major/ minor, lower major/minor) |
For the unrestrained length calculation:
See: Stiffness |
| Wall support | |
|---|---|
| Angles (Fx/Fy/Fz, Mx/My/Mz) |
Used to specify the translational and rotational degrees of freedom in which the support acts:
|
| Translational stiffnesses (x/y/z) |
Used to specify the translational stiffness applied in a direction that is not fixed:
|
| Rotational stiffnesses (x/y/z) |
Used to specify the rotational stiffness applied in a direction that is not fixed:
|
| Panel 1, 2, 3 etc. | |
|---|---|
|
In a multi-panel wall properties can be entered for a specific panel, over-riding those defined at the All panels level. |
|
| Restrained | |
|---|---|
|
|
Used to indicate at which levels the wall is restrained. Note: Only
levels with a connecting member are listed.
|
| Meshing | |
|---|---|
| Override Model’s | Select this checkbox to override the default wall mesh size that is specified in the Structure properties. |
| Wall Mesh Horizontal Size | Used to override the default wall horizontal mesh size (1.000m). |
| Wall Mesh Vertical Size | Used to override the default wall vertical mesh size (1.000m). |
| Wall Mesh Type |
Available mesh types:
|
| UDA | |
|---|---|
|
Name Finish Class Phase Note File |
A customizable list of the attributes that can be applied to individual members and panels. |