You can create meshed masonry walls in level, frame, or structure views. For detailed information on creating masonry walls, see the following instructions.

Material type

The Grade lists all the available Masonry materials in the Materials database under the current regional code.

Note: Currently there are three built-in masonry material grades for the US regional code only.

If the grade you want to use is not listed, you can open the Materials dialog and add the grade to the database.

Geometric rules

  • Masonry walls must be rectangular in a vertical plane.
  • Openings are permitted in masonry walls.
  • The alignment and offsets in the wall properties are not structurally significant as they have no affect on the solver elements that are formed in the solver model.
  • Masonry meshed walls cannot be included in cores.

Sub-division of meshed walls

Each wall object is split into separate panels only at those construction levels where an element or slab attaches to the wall. At the levels where the wall has been split, wall beam elements are also inserted.

Create masonry walls in a level view

  1. On the Model tab, in the Walls group, click the arrow below the wall type droplist and pick Masonry Meshed.
  2. Go to the Properties window.
  3. Use the Grade property to select the masonry grade.
  4. Adjust the top and base level for the wall, if necessary.
  5. Adjust the remaining properties, such as the wall thickness, if necessary.
  6. In the model, click the start point of the wall.
  7. Click the end point of the wall.

    Tekla Structural Designer creates the wall.

Create masonry walls in a frame or structure view

Note: In order to define a wall in a frame or structure view, you must have already defined the construction levels between which the wall will run, and the grid points between which it will lie.
  1. On the Model tab, in the Walls group, click the arrow below the wall type droplist and pick Masonry Meshed.
  2. Go to the Properties window.
    Because the Material type is Masonry, the Rectangular property cannot be unselected.
  3. Use the Grade property to select the masonry grade.
  4. Adjust the remaining properties, such as the wall thickness, if necessary.
  5. Click a point to define a corner of the wall.
  6. Click a point to define the opposite corner.
    Tekla Structural Designer creates the wall between the selected two points.

Masonry wall properties

Select one or more masonry wall and then use the Properties window to view and modify their properties.

General
Name The automatically generated name.
User Name Can be used to override the automatically generated name if required.
Top Level Specifies the top level for the wall.
Base Level Specifies the bottom level for the wall.
Wall Type

Meshed Shear Wall

Note: For masonry walls the wall type can only be a meshed shear wall.
AutomaticGenerate Support

Cleared - a support will only be created if the Generate support property is selected.

Selected - a support will only be created if no members/slabs capable of providing support exist under the wall.

Generate support

Cleared - no support is created under the wall.

Selected - a support is created under the wall.

Note: When a support is created, a line support is formed under a meshed wall.
Note: When a support is created, its degrees of freedom are as specified in the ‘Wall support’ area of the wall properties.

KLL

(Head Code ACI/AISC)

Specify the KLL factor in accordance with Table 4-2 in ASCE 7-05/ASCE 7-10.

See: Overview of live or imposed load reductions

Plane Indicates the grid along which the wall is placed.
All panels
Grade The masonry grades that are available here are set from the Materials button on the Home ribbon.
Thickness

The actual thickness of the wall (not nominal).

Grout
  • Fully grouted
  • Partially grouted
  • Ungrouted
Grout spacing
Alignment

Alignment of the wall:

  • Front
  • Back
  • Middle
  • User
Alignment offset When the alignment is set to User it can be adjusted by specifying an exact offset.
End 1 extension

The amount the wall is extended or trimmed back from end 1.

A positive extension extends the wall length beyond its insertion point.

A negative extension trims the wall back from the insertion point.

See: Apply wall extensions

Note:

End 1 and End 2 are identified by switching on Walls > Direction in Scene Content.

They are assigned according to the two points clicked on when the wall is created as follows.

If the two points are at the same elevation - End 1 is at the first point clicked.

If the points at different elevations - End 1 is at the lowest of the two points.

End 2 extension

The amount the wall is extended or trimmed back from end 2.

A positive extension extends the wall length beyond its insertion point.

A negative extension trims the wall back from the insertion point.

See: Apply wall extensions

Releases

Minor Top,

Minor Bottom

Fixed

Pinned

Continuous (incoming members pinned)

For further details, see: Wall releases

Edge 1,

Edge 1

Fixed

Pinned

Continuous (incoming members pinned)

For further details, see: Wall releases

Live Load reduction [ACI/AISC], Imposed Load reduction [Other codes]

Override calculated value

This option allows the user to specify their own percentage of load reduction to cater for situations where the automatically calculated value is inappropriate.

See: Overview of live or imposed load reductions

Analysis & design control
Orthotropic By default, the wall panels are treated as having isotropic material properties. Selecting this option allows assigning orthotropic material properties.

For further details, see: Orthotropic walls

Calculation
Only available when the Orthotropic option has been selected.
  • No calculation
  • Apply X and Y factors - Allows setting material properties in two in-plane directions automatically based on the stiffness modification X and Y factors below.

    For details of how the parameters are calculated, see: Orthotropic wall implementation

  • Apply section adjustment factors - this option is only available for the US (AISC/ACI) region. Orthotropic properties are then calculated based on section properties of the selected primary bending axis, (i.e. Major or Minor).

X factor - along the length of the wall.

Y factor - along the height of the wall.

These are only available when the Apply X and Y factors Calculation option has been selected.

Applies stiffness modification factors in the local X and Y directions

Bending axis adjustment, Ey

This is only available when the Apply section adjustment factors Calculation option has been selected.

Allows you to select the primary bending axis, (Major or Minor) to be used in orthotropic property calculations.

Ex, Ey, Gxy, Gxz | Gyz, 𝜈x, and 𝜈y

Material properties, such as Young’s moduli, shear moduli, and the Poisson’s ratio can be manually set using these fields.

They are only editable for Orthotropic walls when the No calculation Calculation option is selected (except 𝜈y, which remains read-only).

They are not initially displayed when the Apply section adjustment factors Calculation option has been selected, but are populated once the analysis is complete.

Note: No distinction is made between Gxz and Gyz out-of-plane shear moduli.
Apply modification factors

By default, (unless the Orthotropic option has been selected), the modification factors specified in Analysis settings are applied. When this option is cleared the modification factors are not applied.

See also: Use of modification factors

Assume cracked

Assuming masonry wall sections are cracked has a direct affect on the analysis; smaller modification factors are applied to cracked sections causing an increase in deflection. Indirectly the design can also be affected because the sway/drift sensitivity calculations are also influenced by this assumption.

See: Cracked, partially cracked, and uncracked concrete members

The Assume cracked option is not available when the Orthotropic option has been selected.

Sway and drift checks
Drift/Seismic drift checks and consider for seismic torsion

By default all stacks of all walls are taken into account in the calculation to determine the sway sensitivity of the building. The results of this calculation being accessed from the Review toolbar.

This parameter provides a facility to exclude particular wall panels from these calculations to avoid spurious results associated with very small panel lengths. You can either clear the checkbox located under ‘All Panels’ to exclude the entire wall, or you can exclude a particular panel by clearing the checkbox located under that panel only.

Wind drift check,

Wind drift ratio

Wind drift is automatically checked against the specified limiting ratio, (which can be set differently for different columns). The results of this calculation are accessed from the Review toolbar.

If you don’t want this check to be performed you can either clear the checkbox located under ‘All Panels’ to exclude the entire wall, or you can exclude a particular stack by clearing the checkbox located under that panel only.

Slenderness

Major / Minor

Braced

Bracing

Note: The bracing and effective length properties of a masonry wall are taken into account when calculating it's effective length, in the same way they are for a reinforced concrete wall (see: Effective length calculations (column and wall: ACI 318). The calculated values are then passed on to Tedds to be used in the design of the wall, where applicable.

Major / Minor effective length factor

Calculated

User input value

Stiffness
Use slab for calculation (upper major/ minor, lower major/minor)

For the unrestrained length calculation:

  • • if a slab exists at a panel end, it can be ignored by unchecking the relevant box.

  • If no slab exists at that end, the setting is redundant - in which case the program considers the setting at the remote end of the next panel instead.

See: Stiffness

Wall support
Angles

(Fx/Fy/Fz, Mx/My/Mz)

Used to specify the translational and rotational degrees of freedom in which the support acts:

  • Fixed - indicates the support is fixed in the specified direction.

  • Free - indicates the support is free to move, or has a stiffness applied in the specified direction.

Translational stiffnesses (x/y/z)

Used to specify the translational stiffness applied in a direction that is not fixed:

  • Release

  • Spring Linear

  • Spring Non-linear

Rotational stiffnesses (x/y/z)

Used to specify the rotational stiffness applied in a direction that is not fixed:

  • Release

  • Spring Linear

  • Spring Non-linear

Panel 1, 2, 3 etc.

In a multi-panel wall properties can be entered for a specific panel, over-riding those defined at the All panels level.

Restrained

Used to indicate at which levels the wall is restrained.

Note: Only levels with a connecting member are listed.
Meshing
Override Model’s Select this checkbox to override the default wall mesh size that is specified in the Structure properties.
Wall Mesh Horizontal Size Used to override the default wall horizontal mesh size (1.000m).
Wall Mesh Vertical Size Used to override the default wall vertical mesh size (1.000m).
Wall Mesh Type

Available mesh types:

  • Quad only
  • Tri only
  • Quad dominant

See: How meshed walls are represented in solver models

UDA

Name

Finish

Class

Phase

Note

File

A customizable list of the attributes that can be applied to individual members and panels.

See: Work with user-defined attributes