Reinforcement area for a wall
-
Limiting minimum ratio of horizontal reinforcement area to gross concrete area, ρh,lim,min
-
Limiting maximum ratio of horizontal reinforcement area to gross concrete area, ρh,lim,max
The minimum area of horizontal reinforcement, Ash,min, is an NDP1:
-
EC2 Recommendations, UK NA, Irish NA, Malaysian NA, Singapore NA, Finnish NA
the recommendation is:
Ash,min = max(0.25 · Asv,prov, 0.001 · Acg)
where
- Asv,prov = actual area of vertical reinforcement provided
- Acg = gross area of the concrete wall
-
Norwegian NA
the recommendation is:
Ash,min = max(0.25 · Asv,prov, (0.3 · Acg · fctm) / fyk)
-
Swedish NA
the recommendation is:
Ash,min = 0.25 · Asv,prov
The minimum reinforcement ratio (of horizontal reinforcement area to gross concrete area), which will be the start point for the design, is specified in Design Settings, with the default being 0.002.
Minimum Horizontal Bar Spacing
Clear distance between bars:2
scl,min ≥ max(k1 · maximum bar diameter, 20 mm, dg + k2)
where dg is the maximum aggregate size.
k1 and k2 are NDP values:
-
EC2 Recommendations, UK NA, Irish NA, Malaysian NA, Singapore NA, Swedish NA
k1 = 1.0, and k2 = 5 mm
-
Finnish NA
k1 = 1.0, and k2 = 3 mm
-
Norwegian NA
k1 = 2.0, and k2 = 5 mm
You are given additional control over the spacing by specifying a minimum clear spacing user limit in Design Settings.
Maximum Horizontal Bar Spacing
To satisfy the slab condition3 if "predominantly out-of-plane bending":
Limiting maximum horizontal spacing, scr,max = min(3 · hw, 400 mm)
You are given control over this value by specifying a maximum centre spacing user limit in Design Settings.
Footnotes