Minimum Longitudinal Bar Diameter
-
EC2 Recommendations, Finnish NA, Swedish NA:
φlong,min = 8 mm
-
Malaysian NA and Norwegian NA:
φlong,min = 10 mm
-
UK NA, Irish NA, and Singapore NA:
φlong,min = 12 mm
Minimum Longitudinal Bar Spacing
-
EC2 Recommendations, UK NA, Irish NA1, Malaysian NA, Singapore NA, Swedish NA:
scl,min ≥ max[maximum longitudinal bar diameter, 20 mm, dg + 5 mm]
-
Finnish NA:
scl,min ≥ max[maximum longitudinal bar diameter, 20 mm, dg + 3 mm]
-
Norwegian NA:
scl,min ≥ max[2 · maximum longitudinal bar diameter, 20 mm, dg + 5 mm]
where dg is the maximum aggregate size.
Maximum Longitudinal Bar Spacing
You are given control over this value by specifying an upper limit in Design Settings > Column > Reinforcement Layout.
Minimum Longitudinal Total Steel Area
If NEd ≥ 0 (i.e. compression):
-
EC2 Recommendations, UK NA, Irish NA2, Malaysian NA, Singapore NA, Finnish NA:
Asl,min = max[(0.1 · NEd) / fyd, 0.2% · column area]
-
Norwegian NA:
Asl,min = max[min((0.2 · Ac · fcd) / fyd, (0.5 · NEd) / fyd), 1.0% · column area]
-
Swedish NA:
Asl,min = 0.2% · column area
Else:
Asl,min = 0.45% · column area
It has been decided that in the tension case, in the absence of clear guidance by EC2, it is responsible and conservative to adopt the 0.45% used by BS8110.
Maximum Longitudinal Total Steel Area
-
EC2 Recommendations, UK NA, Irish NA3, Malaysian NA, Singapore NA:
Asl,max = 4% · column area (8% in lap regions)
-
Finnish NA:
Asl,max = 6% · column area (12% in lap regions)
-
Norwegian NA:
Asl,max = 4% · net concrete area (8% in lap regions)
-
Swedish NA:
Maximum area of reinforcement is not limited
Long Term Compressive Strength Factor
-
UK NA, Irish NA, Malaysian NA, Singapore NA, Finnish NA, Norwegian NA4:
αcc = 0.85
-
EC2 Recommendations, Swedish NA:
αcc = 1.0
Design Concrete Compressive Strength for Shear
fcd = αcc · fck / γC
-
EC2 Recommendations, UK NA, Irish NA, Malaysian NA, Singapore NA, Finnish NA, Norwegian NA, Swedish NA:
γC = 1.50
Footnotes