Skip to main content

Design parameters for longitudinal bars (concrete column: EC2)

Modified: 9 Nov 2026 Tekla Structural Designer 2025
2025
Tekla Structural Designer
For some of the longitudinal reinforcement design parameters, additional user defined limits can be applied - where this is the case minimum and maximum values are specified in Design Settings > Concrete > Cast-in-place > Column > Reinforcement Layout. These are considered in addition to the EC2 or NA recommendations.

Minimum Longitudinal Bar Diameter

For design in accordance with:
  • EC2 Recommendations, Finnish NA, Swedish NA:

    φlong,min = 8 mm

  • Malaysian NA and Norwegian NA:

    φlong,min = 10 mm

  • UK NA, Irish NA, and Singapore NA:

    φlong,min = 12 mm

Minimum Longitudinal Bar Spacing

For design to:
  • EC2 Recommendations, UK NA, Irish NA1, Malaysian NA, Singapore NA, Swedish NA:

    scl,min ≥ max[maximum longitudinal bar diameter, 20 mm, dg + 5 mm]

  • Finnish NA:

    scl,min ≥ max[maximum longitudinal bar diameter, 20 mm, dg + 3 mm]

  • Norwegian NA:

    scl,min ≥ max[2 · maximum longitudinal bar diameter, 20 mm, dg + 5 mm]

    where dg is the maximum aggregate size.

Maximum Longitudinal Bar Spacing

You are given control over this value by specifying an upper limit in Design Settings > Column > Reinforcement Layout.

Minimum Longitudinal Total Steel Area

If NEd ≥ 0 (i.e. compression):

For design to
  • EC2 Recommendations, UK NA, Irish NA2, Malaysian NA, Singapore NA, Finnish NA:

    Asl,min = max[(0.1 · NEd) / fyd, 0.2% · column area]

  • Norwegian NA:

    Asl,min = max[min((0.2 · Ac · fcd) / fyd, (0.5 · NEd) / fyd), 1.0% · column area]

  • Swedish NA:

    Asl,min = 0.2% · column area

Else:

Asl,min = 0.45% · column area

Note:

It has been decided that in the tension case, in the absence of clear guidance by EC2, it is responsible and conservative to adopt the 0.45% used by BS8110.

Maximum Longitudinal Total Steel Area

For design to:
  • EC2 Recommendations, UK NA, Irish NA3, Malaysian NA, Singapore NA:

    Asl,max = 4% · column area (8% in lap regions)

  • Finnish NA:

    Asl,max = 6% · column area (12% in lap regions)

  • Norwegian NA:

    Asl,max = 4% · net concrete area (8% in lap regions)

  • Swedish NA:

    Maximum area of reinforcement is not limited

Long Term Compressive Strength Factor

For design in accordance with:
  • UK NA, Irish NA, Malaysian NA, Singapore NA, Finnish NA, Norwegian NA4:

    αcc = 0.85

  • EC2 Recommendations, Swedish NA:

    αcc = 1.0

Design Concrete Compressive Strength for Shear

fcd = αcc · fck / γC

For design to 5:
  • EC2 Recommendations, UK NA, Irish NA, Malaysian NA, Singapore NA, Finnish NA, Norwegian NA, Swedish NA:

    γC = 1.50

Footnotes

1 EN 1992-1-1:2004 Section 8.2
2 EN 1992-1-1:2004 Section 9.5.2(2)
3 EN 1992-1-1:2004 Section 9.5.2(3)
4 EN 1992-1-1:2004 Section 3.1.6(1)
5 EN 1992-1-1:2004 Section 3.1.6(1)