Construction Stage design checks (Composite beams: EC4)
When you design or check a beam for the construction stage (the beam is acting alone before composite action is achieved) the following conditions are examined in accordance with EC3:
-
section classification (EC3 Table 5.2),
-
major axis shear capacity (EC3 clause 6.2.6 (1)),
-
web shear buckling (EC3 clause 6.2.6 (6)),
-
moment capacity:
-
EC3 Equation 6.13 for the low shear condition,
-
EC3 Equation 6.29 for the high shear condition,
-
-
lateral torsional buckling resistance (EC3 clause 6.3.2.3),
Note:This condition is only checked in those cases where the profile decking does not provide adequate restraint to the beam.
- construction stage total load deflection check.
Composite stage design checks
When you design or check a beam for the composite stage (the beam and concrete act together, with shear interaction being achieved by appropriate shear connectors) the following Ultimate limit state and Serviceability limit state conditions are examined in accordance with EC4, unless specifically noted otherwise.
Ultimate limit state checks
-
section classification - the classification system defined in EC3 clause 5.5.2 applies to cross-sections of composite beams,
-
vertical shear capacity in accordance with EC3 clause 6.2.6,
-
longitudinal shear capacity allowing for the profiled metal decking, transverse reinforcement and other reinforcement which has been defined,
-
number of shear connectors required (EC4 clause 6.6.1.3 (5)) between the point of maximum moment and the end of the beam, or from and between the positions of significant point loads,
-
moment capacity,
-
web openings.
Serviceability limit state checks
-
service stresses - although there is no requirement to check these in EC4 for buildings (EC4 clause 7.2.2), concrete and steel top/bottom flange stresses are calculated but only reported if the stress limit is exceeded.
-
deflections,
-
self-weight,
-
SLAB loadcase,
-
dead load,
-
imposed load,
-
total deflections,
-
-
-
natural frequency check.