Pad base shear design check
Calculate tension reinforcement ratio (cl. 6.2.2(1)):
ρl = min(Asl / (L · d), 0.02)
where
- Asl = area of tension reinforcement
- L = unit width of foundation in which Asl is provided
- d = effective depth of reinforcement in direction considered
- Fy,sup = horizontal force acting on support Y-direction in STR/GEO limit states - from analysis
Calculate k (cl. 6.2.2(1)):
k = min(1 + (200 mm / d)1/2, 2.0)
Calculate minimum shear strength (NDP) (cl. 6.2.2(1)):
vmin = 0.035 · k3/2 · fck1/2 for EC2 recommendations
vmin = 0.035 · k3/2 · fck1/2 for UK, Irish, Malaysian, and Singapore NA
Calculate resistance without shear reinforcement for X and Y directions (cl. 6.2.2(1)):
vRd,c,x = max(CRd,c · k · (100 N2/mm4 · ρl · fck)1/3, vmin)
vRd,c,y = max(CRd,c · k · (100 N2/mm4 · ρl · fck)1/3, vmin)
Maximum allowable shear resistance (cl. 6.2.2(6)):
vRd,max = 0.5 · v · fcd
where
- fcd = concrete design compressive strength
- v = cracked concrete reduction factor
If applied design shear force is less than or equal to the shear resistance, i.e. vEd ≤ vRd = min(vRd,c, vRd,max), the foundation thickness is adequate for beam shear.
Strip base shear design check
The principle of the strip base shear design check is similar to that for the pad base. Only direction X is checked (around Y-axis) using segment widths.