Skip to main content

Design for shear (pad and strip base:EC2)

Modified: 6 Nov 2026 Tekla Structural Designer 2025
2025
Tekla Structural Designer

Pad base shear design check

Calculate tension reinforcement ratio (cl. 6.2.2(1)):

ρl = min(Asl / (L · d), 0.02)

where

  • Asl = area of tension reinforcement
  • L = unit width of foundation in which Asl is provided
  • d = effective depth of reinforcement in direction considered
  • Fy,sup = horizontal force acting on support Y-direction in STR/GEO limit states - from analysis

Calculate k (cl. 6.2.2(1)):

k = min(1 + (200 mm / d)1/2, 2.0)

Calculate minimum shear strength (NDP) (cl. 6.2.2(1)):

vmin = 0.035 · k3/2 · fck1/2 for EC2 recommendations

vmin = 0.035 · k3/2 · fck1/2 for UK, Irish, Malaysian, and Singapore NA

Calculate resistance without shear reinforcement for X and Y directions (cl. 6.2.2(1)):

vRd,c,x = max(CRd,c · k · (100 N2/mm4 · ρl · fck)1/3, vmin)

vRd,c,y = max(CRd,c · k · (100 N2/mm4 · ρl · fck)1/3, vmin)

Maximum allowable shear resistance (cl. 6.2.2(6)):

vRd,max = 0.5 · v · fcd

where

  • fcd = concrete design compressive strength
  • v = cracked concrete reduction factor

If applied design shear force is less than or equal to the shear resistance, i.e. vEd ≤ vRd = min(vRd,c, vRd,max), the foundation thickness is adequate for beam shear.

Strip base shear design check

The principle of the strip base shear design check is similar to that for the pad base. Only direction X is checked (around Y-axis) using segment widths.

Submit