Tekla Structures 2025 US environment Release Notes
Below you will find the release notes specific to the US environment for Tekla Structures 2025.
Project User-defined attribute tabs updated & aligned between disciplines
Project level User-defined attributes have been standardized. This standardization effort merges previously discipline-specific tabs customizations into all roles. The main goal is to streamline the user experience and ensure consistency across tabs and different roles.
Notable updates to Project Team and Subcontractor Team tabs:
- Fax attributes removed.
- Desc/Website attributes replaced with with Website attributes.
- Contact, Email & Project # (where previously non-existent) attributes added.
Project Team tab Attribute name changes
| Old | New | ||
|---|---|---|---|
| Display name | Attribute name | Display name | Attribute name |
| General Contractor: Project Number | PROJECT_NUMBER | GENERAL CONTRACTOR: Project # | GC_PRJ_NUMBER |
| Owner | PROJECT_OWNER | OWNER: Name | OWNER |
| Desc/Website | OWNER_DESCR | Website | OWNER_URL |
| Architect | PROJECT_ARCHITECT | ARCHITECT: Name | ARCH |
| Main Contact | DESIGN_CONTACT | Contact | ARCH_CONTACT |
| Address | DESIGN_ADDRESS | Address Line 1 | ARCH_ADDRESS |
| City/State | DESIGN_ADDRESS | City/State/Zip | ARCH_CITY_ST |
| Desc/Website | DESIGN_DESCR | Website | ARCH_URL |
| Engineer Team | ENG_INFO | ENGINEER: Name | ENG |
| Main Contact | ENG_CONTACT | Contact | ENG_CONTACT |
| Desc/Website | ENG_DESCR | Website | ENG_URL |
Subcontractor Team tab Attribute name changes
| Old | New | ||
|---|---|---|---|
| Display name | Attribute name | Display name | Attribute name |
| Concrete Subcontractor | SUB_CONTRACTOR1 | CONCRETE SUBCONTRACTOR: Name | CONC_SUB |
| Main Contact | SUB_CONTACT1 | Contact | CONC_SUB_CONTACT |
| Address | SUB_ADDRESS1 | Address Line 1 | CONC_SUB_ADDRESS |
| City/State | SUB_CITY_ST1 | City/State/Zip | CONC_SUB_CITY_ST |
| Phone | SUB_PHONE1 | Phone | CONC_SUB_PHONE |
| Desc/Website | SUB_DESCR1 | Website | CONC_SUB_URL |
| Electrical Subcontractor | SUB_CONTRACTOR2 | ELECTRICAL SUBCONTRACTOR: Name | ELEC_SUB |
| Main Contact | SUB_CONTACT2 | Contact | ELEC_SUB_CONTACT |
| Address | SUB_ADDRESS2 | Address Line 1 | ELEC_SUB_ADDRESS |
| City/State | SUB_CITY_ST2 | City/State/Zip | ELEC_SUB_CITY_ST |
| Phone | SUB_PHONE2 | Phone | ELEC_SUB_PHONE |
| Desc/Website | SUB_DESCR2 | Website | ELEC_SUB_URL |
| Mechanical Subcontractor | SUB_CONTRACTOR3 | MECHANICAL SUBCONTRACTOR: Name | MECH_SUB |
| Main Contact | SUB_CONTACT3 | Contact | MECH_SUB_CONTACT |
| Address | SUB_ADDRESS3 | Address Line 1 | MECH_SUB_ADDRESS |
| City/State | SUB_CITY_ST3 | City/State/Zip | MECH_SUB_CITY_ST |
| Phone | SUB_PHONE3 | Phone | MECH_SUB_PHONE |
| Desc/Website | SUB_DESCR3 | Website | MECH_SUB_URL |
| Plumbing Subcontractor | SUB_CONTRACTOR4 | PLUMBING SUBCONTRACTOR: Name | PLUMB_SUB |
| Main Contact | SUB_CONTACT4 | Contact | PLUMB_SUB_CONTACT |
| Address | SUB_ADDRESS4 | Address Line 1 | PLUMB_SUB_ADDRESS |
| City/State | SUB_CITY_ST4 | City/State/Zip | PLUMB_SUB_CITY_ST |
| Phone | SUB_PHONE4 | Phone | PLUMB_SUB_PHONE |
| Desc/Website | SUB_DESCR4 | Website | PLUMB_SUB_URL |
Fabrication Team (was Fabricator Information) tab Attribute name changes
| Old | New | ||
|---|---|---|---|
| Display name | Attribute name | Display name | Attribute name |
| Fabricator Desc/Website | FAB_DESCR | FABRICATOR: Website | FAB_URL |
| Detailer Name | DET_NAME | DETAILER: Name | DET |
| Detailer Desc/Website | DET_DESCR | Website | DET_URL |
Potential Template Updates for Backwards Compatibility
For the updated Attribute names, it is possible to retain backwards compatibility to the old Attribute names using a Conditional structure (if/then statement) that checks if the old attribute name has a value
IsSet("<OldAttributeName>") && GetValue("<OldAttributeName>") != ""and if it does then output the value
GetValue("<OldAttributeName>")otherwise/else
GetValue("<NewAttributeName>")
Below is an example Conditional structure that could be used for backwards compatibility for the update from PROJECT_OWNER to OWNER:
if (IsSet("PROJECT.USERDEFINED.PROJECT_OWNER") && GetValue("PROJECT.USERDEFINED.PROJECT_OWNER") != "")
then GetValue("PROJECT.USERDEFINED.PROJECT_OWNER")
else
GetValue("PROJECT.USERDEFINED.OWNER")
endifNew Steel Standards Project User-defined attribute tab
The Steel Detailing Role Project standards Project UDA tab has been replaced with a new Steel Standards with additional fields.
Steel Standards (previously Project standards) tab Attribute name changes
| Old | New | ||
|---|---|---|---|
| Display name | Attribute name | Display name | Attribute name |
| Project Std. Paint | PROJECT_STD_PAINT | Coating | PRJ_COAT |
PRJ_CUST_COAT | |||
PRJ_CUST_COAT2 | |||
PRJ_COAT_COLOR | |||
| Project Std. Finish | PROJECT_FINISH | AESS Category | PRJ_STD_AESS |
| Misc. Joint Finish | PRJ_STD_MISC | ||
| Surface Prep. | PRJ_STD_PREP | ||
| Project Std. Paint Mil Thickness | PROJECT_MIL_THICK | Coat Thickness | PRJ_COAT_THK |
| Project Std. Bolt Grade | PROJECT_STD_BOLT | SHOP STANDARDS: Bolts | PRJ_STD_S_diameter |
PRJ_STD_S_screwdin | |||
| FIELD STANDARDS: Bolts | PRJ_STD_F_diameter | ||
PRJ_STD_F_screwdin | |||
| Project Std. Hole Diameter | PROJECT_STD_HOLE_DI | Hole Diameter | PRJ_S_HOLE_DIA |
| Project Std. Material Spec | PROJECT_STD_MATL | Material | PRJ_STD_MATL |
| Project Std. Field Connx. | PROJECT_STD_CONNX | Connection | PRJ_STD_CONNX |
| Project Std. Welds | PROJECT_STD_WELD | SHOP STANDARDS: Welds | PRJ_STD_S_WELD |
| FIELD STANDARDS: Welds | PRJ_STD_F_WELD | ||
| Project Std. Electrodes | PROJECT_ELECTRODE | SHOP STANDARDS: Weld Electrodes | PRJ_S_ELECT |
| FIELD STANDARDS: Weld Electrodes | PRJ_STD_F_ELECT | ||
| Project Std. Cope Radius | PROJECT_STD_COPE | Cope Radius | PRJ_STD_COPE |
SHOP STANDARDS
AESS Category — PROJECT.USERDEFINED.PRJ_STD_AESS
Dropdown menu with vales per ANSI/AISC 303-22: Code of Standard Practice for Steel Buildings and Bridges Section 10.1.1 and Table 10.1 AESS Category Matrix.
Misc. Joint Finish — PROJECT.USERDEFINED.PRJ_STD_MISC
Dropdown menu with vales per National Ornamental and Miscellaneous Metals Association Joint Finish Guidelines.
Material — PROJECT.USERDEFINED.PRJ_STD_MATL
String (alphanumeric text) input field.
Bolts — PROJECT.USERDEFINED.PRJ_STD_S_diameter & PROJECT.USERDEFINED.PRJ_STD_S_screwdin
Two dropdown menus for Bolt size and Bolt standard; these values are populated from the Bolt catalog.
Hole Diameter — PROJECT.USERDEFINED.PRJ_S_HOLE_DIA
Dimension input field. When inputting values, if the XS_INCH_SIGN_ALWAYS is set to FALSE, inch marks will not show.
Cope Radius — PROJECT.USERDEFINED.PRJ_STD_COPE
Dimension input field. When inputting values, if the XS_INCH_SIGN_ALWAYS is set to FALSE, inch marks will not show.
Welds — PROJECT.USERDEFINED.PRJ_STD_S_WELD
String (alphanumeric text) input field.
Weld Electrodes — PROJECT.USERDEFINED.PRJ_S_ELECT
String (alphanumeric text) input field.
FIELD STANDARDS
Connection — PROJECT.USERDEFINED.PRJ_STD_CONNX
String (alphanumeric text) input field.
Bolts — PROJECT.USERDEFINED.PRJ_STD_F_diameter & PROJECT.USERDEFINED.PRJ_STD_F_screwdin
Two dropdown menus for Bolt size and Bolt standard; these values are populated from the Bolt catalog.
Welds — PROJECT.USERDEFINED.PRJ_STD_F_WELD
String (alphanumeric text) input field.
Weld Electrodes — PROJECT.USERDEFINED.PRJ_STD_F_ELECT
String (alphanumeric text) input field.
FINISH/COATING
Surface Prep. — PROJECT.USERDEFINED.PRJ_STD_AESS
Dropdown menu with vales per ANSI/AISC 325 Steel Construction Manual, 16th Ed. Table 2-7 Summary of Surface Preparation Standards. STD STRUCT is the default value.
Coating — PROJECT.USERDEFINED.PRJ_STD_AESS
There are five options in the dropdown menu: CUSTOM, GALVANIZED, NONE, POWDER COAT, & STD SHOP PRIMER (default).
Custom 1 — PROJECT.USERDEFINED.PRJ_CUST_COAT
String (alphanumeric text) input field. Activate only when Coating: CUSTOM is selected.
Custom 2 — PROJECT.USERDEFINED.PRJ_CUST_COAT2
String (alphanumeric text) input field. Activate only when Coating: CUSTOM is selected.
Color — PROJECT.USERDEFINED.PRJ_COAT_COLOR
String (alphanumeric text) input field. Not active only when Coating: NONE is selected.
Coat Thickness — PROJECT.USERDEFINED.PRJ_COAT_THK
String (alphanumeric text) input field. Not active only when Coating: NONE is selected.
Drawing Templates Updated for Steel Standards attribute names
The drawing templates value fields for the corresponding legacy—removed—Project standards tab have been updated to per the new Steel Standards tab attribute names.
TSLOC-7739, TSLOC-8992
Additional line types in drawings
Line types from ..\Environments\common\inp\TeklaStructures.lin have been merged with the US environment's ..\Environments\USA\Common\General\UserDefined\TeklaStructures.lin. The new ones end in 2 and are ½ scale.
Folder structure updates to align with the common environment
..\USA\Common\General\profil directory has been added and ImportExport has been renamed to Collaboration (colaboracion in Latinoamerica) to maintain consistency with main installation common environment.
TSLOC-8986, TSLOC-8823
User-defined attribute files split by object type and tab to align with the common environment
Extending the Reorganization of the common\inp folder, the US environment inp files have been separated into more manageable and understandable files. The naming convention is objects_<TYPE>_<ORIGIN ENVIRONMENT>_<TAB>.inp.
TSLOC-7729
End Prep User-defined attributes have been improved
End Preps for this Member in BOM User-defined attribute dropdown list has been updated to clarify what will be shown. The BOM templates have also been updated for the change.
To update templates from older versions, the formula line for end prep overrides needs to be changed from
if GetValue("USERDEFINED.END_PREP") == "Yes" thento
if GetValue("USERDEFINED.END_PREP_LIST") != "Auto" thenTSLOC-8830
Optimized the use of screen space in ribbons
Optimized the use of screen space by consolidating whitespace in the ribbons. This enhancement aims to provide a more compact and efficient user interface, allowing users to maximize their workspace and improve overall productivity.
TSLOC-8820
Document manager and Reports added to Quick Access Toolbar
Added the Document Manager and Reports split buttons to the Quick Access Toolbar to enhance user productivity and streamline access to these frequently used commands. We believe these improvements will significantly benefit users by making essential tools more accessible and easier to use.
For more information, see Customize the ribbon and Distribute customized ribbons by using a firm or environment folder.
TSLOC-8824
Ribbons are more aligned between Roles
Ribbons for the Steel and Concrete roles have been standardized. This standardization effort merges various discipline-specific customizations into each role based on industry expertise. The main goal is to streamline the user experience and ensure consistency across different roles.
TSLOC-8819
Changes to parametric profile names in profitab.inp
To better align the US environment with Core updates and include additional profiles, profitab.inp has been merged with the core. The following profile definitions were removed from US Environment and replaced by the ones from Tekla Global common.
| Old | New |
|---|---|
| AS_PNL_T | PNL_C |
| AS_PNL_TA | PNL_D |
| AS_PNL_TB | PNL_E |
| AS_PNL_TG | PNL_F |
| BORDER | PNL_A |
| RCSS | PRMD |
| RECTC | PNL_A |
| RECTCC | PNL_G |
| RESS | PRMD |
| RSTR | PNL_A |
| S_PNL | PNL_G |
| S_PNL_T | PNL_H |
The following parametric profile alias definitions were removed from the US Environment because they potentially cause erroneous errors to display and/or have standard dimensions that do not very.
No parametric profiles or their fixed profiles were removed. If additional fixed profiles are desired, it is recommended to Create a fixed profile by copying an existing profile with the industry standard dimensions.
| GLB_ | PSL_ | S4S_ |
| LSL_ | RB_ | TJI_ |
| LVL_ | RS_ |
TSLOC-8872, TSLOC-8838
For more information on parametric profiles and the profitab.inp, see Files related to catalogs, the Add profile definitions to the profitab.inp file, Properties used in profitab.inp sections of the Create parametric profiles using .clb files product guide, and Create a fixed profile by copying an existing profile section of the Create fixed profiles product guide..
Masonry materials added to Material Catalog for Tekla Structural Designer linking
Tekla Structural Designer 2025 enhances the design of masonry walls. In order to integrate these items with Tekla Structures, the following materials have been added.
| Role Unit | Additional Materials |
|---|---|
| Imperial | 8 in CMU wall - 2500 psi (3250 psi/S) 10 in CMU wall - 2500 psi (3250 psi/S) 12 in CMU wall - 2500 psi (3250 psi/S) |
| Metric | 200 mm CMU wall - 17.2 MPa (22.4 MPA/S) 250 mm CMU wall - 17.2 MPa (22.4 MPA/S) 305 mm CMU wall - 17.2 MPa (22.4 MPA/S) |
TSLOC-8985
Fix list
| Defect Number | Development Area | Description |
|---|---|---|
| TSLOC-7044 | User-defined attributes | Fastrak (Building Designer) was replaced by Tekla Structural Designer in 2016. The tab was retained for legacy versions, it is now removed. |
| TSLOC-8943 | Advanced options | Removed Zero-width space characters from .ini files: Some .ini files had Zero-width space character (ZWSP) non-printing characters present. These have been removed from the .ini files. |
| TSLOC-8827 | User-defined attributes | Previously Concrete parts had two sets of Concrete covers for rebar sets. The duplicating ConcreteCover tab was removed. |
| TSLOC-8832 | User-defined attributes | To facilitate translations to other languages, the "Yes" and "No" UDAs have been updated with translatable values. |