Deflection control
Tekla Structural Designer implements both a simplified, and also a more rigorous method for controlling deflection.
The actual method applied to a specific beam will depend upon whether it is required to support sensitive finishes.
When the rigorous method is applied, immediate short-term deflections, and also long-term deflections resulting from creep and shrinkage of flexural members are considered.
Structure supporting sensitive finishes
Any beam that supports or is attached to partitions or other constructions likely be damaged by large deflections should be identified as such by selecting Structure supporting sensitive finishes under the located under the Analysis & design control heading in the beam properties.
The deflection method applied to the beam depends on this setting as follows:
- beams not required to support sensitive finishes adopt the simplified method.
- beams required to support sensitive finishes adopt the rigorous method.
The simplified method
For those beams that have not being chosen to support sensitive finishes, deflection is controlled by the simplified method of limiting the span to depth ratio.
This check can be satisfied by providing a total beam depth which exceeds hmin, (where hmin depends on the clear span and beam end conditions).
If this check is not satisfied the beam is then rechecked by the rigorous method.
The rigorous method
For beams that do not meet minimum thickness requirements determined by the simplified method, or that support sensitive finishes, deflections should be calculated by rigorous method.
The parameters listed below directly affect the rigorous calculation method and hence require consideration:
- Does the beam support sensitive finishes?
If the Structure supporting sensitive finishes beam property (located under the located under the Analysis & design control heading) is cleared the simplified method may suffice in which case rigorous calculations are not required.
- Can the beam flanges be taken into account?
Selecting Consider flanges (located under the located under the Analysis & design control heading) can assist in reducing the calculated deflections.
- Does the beam contain compression steel?
In the current release of the program it has been assumed that the beam always contains compression steel for the rigorous method deflection calculations.
- Are the deflection limits appropriate?
- These limits are editable in the beam properties, the default ratios being span/360 for live load, and span/480 for total load affecting sensitive finishes.
- The default span\over limits tend to produce conservative results.
- You are also given the flexibility to specify absolute deflection limits as an alternative, or in addition to the above span\over limits.
- Is the long term deflection period correctly specified?
The default value is 5 years, but this can be edited via Design Options > Beam > General Parameters.
- Is the time at which brittle finishes are introduced correctly specified?
The default value is 1 month, but this can be edited via Design Options > Beam > General Parameters.
- Are the percentages of dead load applied prior to brittle finishes and long term live load correctly specified?
The deflection check takes account of these percentages, (defaulting to 50% of dead load applied prior to brittle finishes and 33% of long term live load). You are able to adjust each of these by selecting the loadcase name from the left hand side of the Loadcases dialog and then adjusting the value.
The simplified method check - limiting span to depth ratio
For beams provision of a minimum overall thickness (min. total depth) as required by the following table satisfies the requirements of the code for members not supporting or attached to partitions or other construction likely be damaged by large deflections.
| Support Conditions | Minimum thickness, ht |
|---|---|
| Simply Supported | ln / 16 |
| One end continuous | ln / 18.5 |
| Both ends continuous | ln / 21 |
| Cantilever | ln / 8 |
If h ≥ hmin, the design passes and no further calculations are required.
where
- h = overall height of member
- hmin = ht · fy,mod
- ht = minimum thickness from above table
- ln = clear span length
- fy,mod = 0.4 + fy / 700 MPa (metric units)
- fy,mod = 0.4 + fy / 100000 psi (US units)
If the deflection check fails the rigorous method below is used.
The rigorous method check
For beams that do not meet minimum thickness requirements above, or that support or are attached to partitions or other constructions likely be damaged by large deflections, deflections are calculated by following method.
- Firstly, the beam’s cracked section moment of inertia, Icr, is calculated.
- Then the cracking moment, Mcr, is calculated.
- The Long Term Deflection Period is read from the user specified value in Design settings. - 3 months to 5 years (default value: 5 years).
- The Time at which brittle finishes are introduced is read from the user specified value in Design settings. - 1 month to 6 month (default value: 1 month).
- For each loadcase with type = "dead", the % of load applied prior to sensitive finishes is read from the user specified value in the loadcase dialog (default value: 50%).
- For each loadcase with type = “imposed”, the % of load which is long term is read from the user specified value in the loadcase dialog (default value: 33%).
- For each span in the element the critical gravity combination is determined from the analysis. The combination reporting the max relative deflection is the one considered in the deflection check.
- The maximum deflections for the different situations below can then be determined:
- Dead load deflection (Δi)d
- Dead and live load deflection (Δi)dlive
- Live load deflection (Δi)live
- Sustained load deflection (Δi)sus
- Total load deflection (Δi)tot
- Deflection affecting sensitive finishes (Δi)af
The check passes if the calculated deflections are less than the deflection limits specified in the beam properties.