Slenderness Ratio
For columns: The slenderness ratio, k · lu / r, of the restrained length (note: not necessarily the stack length – it will be longer if there is no restraint at either end of the stack) about each axis is calculated as follows:
(k · lu / r)y = k · lu,y / √(Iy / Ag)
(k · lu / r)z = k · lu,z / √(Iz / Ag)
where
- k · lu / r = slenderness ratio
- k = effective length factor
- lu,y = unsupported column length with respect to major axis (y-axis)
- lu,z = unsupported column length with respect to minor axis (z-axis)
- ry = radius of gyration of the column in the y-direction
- rz = radius of gyration of the column in the z-direction
- Iy = second moment of area of the stack section about the major axis (y-axis)
- Iz = second moment of area of the stack section about the minor axis (z-axis)
- Ag = cross-sectional area of the stack section
For unbraced columns:
If (k · lu / r)y ≤ 22:
then slenderness can be neglected and column can be designed as a short column,
else, column is considered as slender.
If (k · lu / r)z ≤ 22:
then slenderness can be neglected and column can be designed as a short column,
else, column is considered as slender.
For braced columns:
If (k · lu / r)y ≤ min(34 − 12 · M1 / M2, 40):
then slenderness can be neglected and column can be designed as a short column,
else, column is considered as slender.
If (k · lu / r)z ≤ min(34 − 12 · M1 / M2, 40):
then slenderness can be neglected and column can be designed as a short column,
else, column is considered as slender.
where
- M1 = smaller factored end moment on the column, taken as positive if member is bent in single curvature and negative if bent in double curvature, given by min(|Mtop|, |Mbot|)
- M2 = larger factored end moment on the column, always taken as positive, given by max(|Mtop|, |Mbot|)