The nominal concrete cover is the distance between the surface of the reinforcement closest to the nearest concrete surface (including links and surface reinforcement where relevant) and the nearest concrete surface.
You are required to set a minimum value for the nominal cover, cnom,u, for the top, bottom, sides, and ends of each beam in the beam properties.
These values are then checked against the nominal limiting cover, cnom,lim, which depends on the diameter of the reinforcement plus an allowance for deviation, Δcdev (specified in Design Settings > Concrete > Cast-in-place > Beam > General Parameters).
Generally, the allowance for deviation, Δcdev, is an NDP.1 The recommended value is 10 mm, but under strict controls it can be reduced to 5 mm.
If cnom,u < cnom,lim, then a warning is displayed in the calculations.
Footnotes