Skip to main content

Effective depth of section (concrete beam: EC2)

Modified: 6 Nov 2026 Tekla Structural Designer 2025
2025
Tekla Structural Designer

For the design of the longitudinal tension reinforcement, the effective depth of a section, d, is defined as the distance from the extreme concrete fiber in compression to the center of gravity of the longitudinal tension reinforcement.

For the design of the longitudinal compression reinforcement, the effective depth in compression, d2, is defined as the distance from the extreme fiber in compression to the center of gravity of the longitudinal compression reinforcement.

rc_beam_effective_depth.png

The designs for the longitudinal and shear reinforcement follow an iterative process.

For the initial design iterations the values of d and d2 are given by:

d = h − cnom,i − φsw,u − 0.5 · φi,u

d2 = cnom,i + φsw,u + 0.5 · φi,u

where

  • h = the overall depth of the concrete section including any slab
  • cnom,i = the nominal cover to the reinforcement in outermost layer in the top or bottom of the beam as appropriate
  • φsw,u = the minimum diameter of the shear reinforcement specified by the user
  • φi,u = the minimum diameter of the reinforcing bars in the outermost layer in the top or bottom of the beam as appropriate as specified by the user

As the iterations proceed, the values of cnom, φsw, and φi vary accordingly and as second and subsequent layers of longitudinal reinforcement are added, the values of d and d2 become the distance to the center of gravity of the reinforcement.