Skip to main content

Design parameters for longitudinal bars (concrete beam: EC2)

Modified: 9 Nov 2026 Tekla Structural Designer 2025
2025
Tekla Structural Designer

For each of these parameters, any user defined limits (as specified in Design Settings > Concrete > Cast-in-place > Beam > Reinforcement Layout) These are considered in addition to the EC2 or NA recommendations.

Minimum diameter of reinforcement

The minimum diameters of reinforcement are set by the user in Design Settings, the initial default values being:

Minimum longitudinal bar size = 12 mm

Minimum side bar size = 16 mm

Minimum link bar size = 8 mm

If the design results in a bar size less than the user specified limits the checks fails.

Maximum diameter of reinforcement

The maximum diameters of reinforcement are set by the user in Design Settings, the initial default values being:

Maximum bar size = 32 mm

Maximum link bar size = 16 mm

If the design results in a bar size greater than the user specified limits the checks fails.

In Section 8.8 of BS EN 1992-1-8:2004, additional rules are specified when "large diameter bars" are used in the design. A large diameter bar is defined as being a bar with a diameter larger than φlarge where φlarge is an NDP value.

For design in accordance with:
  • EC2 Recommendations, Finnish NA, Norwegian NA, Swedish NA:

    φlarge = 32 mm

  • UK NA, Irish NA, Malaysian NA, Singapore NA:

    φlarge = 40 mm

In the current release the provisions of Section 8.8 are not implemented. If the design results in a bar size with φ > φlarge then a warning is displayed to this effect, advising that the user should take account of the provisions of Section 8.8 when preparing the final design.

Note:

Clause 7.3.3 (2) indicates that cracking can be controlled either by restricting the bar diameter or the max spacing. Tekla Structural Designer adopts the latter approach using Table 7.3N - therefore the maximum bar diameters specified in Table 7.2N are not checked.

Minimum distance between bars

The minimum clear horizontal distance between individual parallel bars, scl,min, is given by:1

scl,min ≥ max[k1 · φ, dg + k2, scl,u,min, 20 mm]

where

  • k1 = the appropriate NDP
  • k2 = the appropriate NDP
  • dg = the maximum size of aggregate
  • φ = the maximum diameter of adjacent bars, φi and φj
  • scl,u,min = user specified minimum clear distance between bars
Note:

To allow you to make decisions regarding access for concrete compaction or size of aggregate, a value for the minimum clear distance between bars can be specified on the appropriate Reinforcement Settings page within Design Settings - separate values being set for bars in the top of a beam and for those in the bottom of a beam.

The minimum clear vertical distance between horizontal layers of parallel bars, scl,min, is given by:

scl,min ≥ max[k1 · φ, dg + k2, 20 mm]

For design in accordance with:
  • EC2 Recommendations, UK NA, Irish NA, Malaysian NA, Singapore NA, Finnish NA, Swedish NA:

    k1 = 1.0

  • Norwegian NA:

    k1 = 2.0

  • EC2 Recommendations, UK NA, Irish NA, Malaysian NA, Singapore NA, Norwegian NA, Swedish NA:

    k2 = 5.0 mm

  • Finnish NA:

    k2 = 3.0 mm

Maximum spacing of tension bars

The maximum centre to centre bar spacing for crack control, scr,max, is dependent on the maximum allowable crack width, wmax, specified in the beam properties from a menu of values which are: 0.20 mm, 0.30 mm, or 0.40 mm with a default value of 0.30 mm.

The service stress in the reinforcement, σs, is given by:

σs = (As,reqd / As,prov) · (fyk / γS) · RPL

where

  • As,reqd = area of reinforcement required for the maximum design Ultimate Limit State moment, MEd
  • As,prov = area of reinforcement provided
  • RPL = permanent load ratio

In the beam properties you are required to supply a value for the permanent load ratio, RPL. A default of 0.65 has been assumed, but you are advised to consider if this is appropriate and adjust as necessary.

The maximum allowable centre to centre bar spacing, scr,max, is then obtained from table 7.3N (shown below) by looking up the calculated value of the service stress in the reinforcement, σs, using interpolation between values of σs.

Steel service stress, σs (N/mm2)

Maximum allowable bar spacing for crack control, scr,max
wmax = 0.40 mm wmax = 0.30 mm wmax = 0.20 mm
≤ 160 300 300 200
200 300 250 150
240 250 200 100
280 200 150 50
320 150 100 Warning
360 100 50 Warning
> 360 Warning Warning Warning

Minimum area of reinforcement

The minimum area of longitudinal tension reinforcement, As,min, is given by:2

As,min ≥ max[kmin1 · bw · d · (fctm / fyk), kmin2 · bw · d]

where

  • kmin1 = the appropriate NDP value
  • kmin2 = the appropriate NDP value
  • fctm = mean value of the axial tensile strength of the concrete
  • fyk = characteristic yield strength of the reinforcement
For design in accordance with:
  • EC2 Recommendations, UK NA, Irish NA, Malaysian NA, Singapore NA, Finnish NA, Norwegian NA, Swedish NA:

    kmin1 = 0.26

    kmin2 = 0.0013

Note:

There is no requirement to have a minimum area of compression reinforcement.

The minimum area of longitudinal tension reinforcement for crack control, As,min,cr, is given by:3

As,min,cr ≥ 0.4 · k · fctm · Act / σs

where

  • k =

    1.0 when h ≤ 300 mm

    0.65 when h ≥ 800 mm

  • fctm = mean value of axial tensile strength of concrete

    0.30 · fck(2/3) for concrete grades ≤ C50/60

    2.12 · ln(1 + ((fck + 8) / 10)) for concrete grades > C50/60

  • σs = the interpolated reinforcement service stress appropriate for the bar spacing of the reinforcement provided
  • Act = area of concrete in tension just before formation of first crack

    = b · y where y = the distance of the Elastic NA from bottom of beam

The minimum area of longitudinal tension reinforcement required, As,min,reqd, is then given by:

As,min,reqd ≥ max(As,min, As,min,cr)

Maximum area of reinforcement

The maximum area of longitudinal tension reinforcement, Ast,max, is given by:4

Ast,max ≤ kmax · Ac

The maximum area of longitudinal compression reinforcement, Asc,max, is given by:

Asc,max ≤ kmax · Ac

where

  • kmax = the appropriate NDP value
  • Ac = the cross sectional area of the beam

    = h · bw

For design in accordance with:
  • EC2 Recommendations, UK NA, Irish NA, Malaysian NA, Singapore NA, Norwegian NA:

    kmax = 0.04

  • Finnish NA, Swedish NA:

    Ast,max = Asc,max = unlimited

Footnotes

1 EN 1992-1-1:2004 Section 8.2(2)
2 EN 1992-1-1:2004 Section 9.2.1.1(1)
3 EN 1992-1-1:2004 Section 7.3.2(2)
4 EN 1992-1-1:2004 Section 9.2.1.1(3)
Submit