Calculate the value of K from:
K = MEd / (fck · bw · d2)
Then calculate the limiting value of K, known as K', from:
K' = (2 · η · αcc / γC) · (1 − λ · (δ − k1) / (2 · k2)) · (λ · (δ − k1) / (2 · k2)) for fck ≤ 50 N/mm2
K' = (2 · η · αcc / γC) · (1 − λ · (δ − k3) / (2 · k4)) · (λ · (δ − k3) / (2 · k4)) for fck > 50 N/mm2
where
- ki = moment redistribution factors
- δ = moment redistribution ratio (= 1.0 in the current release)
- γC = the NDP partial safety factor for concrete
- αcc = coefficient to take account of long term effects on compressive strength of concrete
- λ = 0.8 for fck ≤ 50 N/mm2
= 0.8 − (fck − 50) / 400 for 50 < fck ≤ 90 N/mm2
- η = 1.0 for fck ≤ 50 N/mm2
= 1.0 − (fck − 50) / 200 for 50 < fck ≤ 90 N/mm2
-
UK NA, Irish NA, Malaysian NA, Singapore NA, Finnish NA, Norwegian NA:
γC = 1.5
αcc = 0.85
-
EC2 Recommendations, Swedish NA:
γC = 1.5
αcc = 1.0
IF K ≤ K' THEN compression reinforcement is not required.
Calculate the lever arm, z, from:
z = min(0.5 · d · [1 + (1 − 2 · K / (η · αcc / γC))0.5], 0.95 · d)
The area of tension reinforcement required is then given by:
Ast,reqd = MEd / (fyd · z)
where
- fyd = fyk / γS
- γS = the NDP partial safety factor for reinforcement
The depth to the neutral axis, xu, is given by:
xu = 2 · (d − z) / λ
-
UK NA, EC2 Recommendations, Irish NA, Malaysian NA, Singapore NA, Finnish NA, Norwegian NA, Swedish NA:
γS = 1.15
IF K > K' THEN compression reinforcement is required.
Calculate the depth to the neutral axis from:
xu = d · (δ − k1) / k2 for fck ≤ 50 N/mm2
xu = d · (δ − k3) / k4 for fck > 50 N/mm2
Calculate the stress in the reinforcement from:
fsc = min(Es · εcu3 · (1 − (d2 / xu)), fyd)
where d2 = the distance from the extreme fibre in compression to the center of gravity of the compression reinforcement
Calculate the limiting bending strength, M', from:
M' = K' · fck · bw · d2
Calculate the lever arm from:
z = 0.5 · d · [1 + (1 − 2 · K' / (η · αcc / γC))0.5]
The area of compression reinforcement required, As2,reqd, is given by:
As2,reqd = (MEd − M') / (fsc · (d − d2))
The area of tension reinforcement required, Ast,reqd, is given by:
Ast,reqd = M' / (fyd · z) + As2,reqd · fsc / fyd