Skip to main content

Design for bending for rectangular sections (concrete beam: EC2)

Modified: 9 Nov 2026 Tekla Structural Designer 2025
2025
Tekla Structural Designer

Calculate the value of K from:

K = MEd / (fck · bw · d2)

Then calculate the limiting value of K, known as K', from:

K' = (2 · η · αcc / γC) · (1 − λ · (δ − k1) / (2 · k2)) · (λ · (δ − k1) / (2 · k2)) for fck ≤ 50 N/mm2

K' = (2 · η · αcc / γC) · (1 − λ · (δ − k3) / (2 · k4)) · (λ · (δ − k3) / (2 · k4)) for fck > 50 N/mm2

where

  • ki = moment redistribution factors
  • δ = moment redistribution ratio (= 1.0 in the current release)
  • γC = the NDP partial safety factor for concrete
  • αcc = coefficient to take account of long term effects on compressive strength of concrete
  • λ = 0.8 for fck ≤ 50 N/mm2

    = 0.8 − (fck − 50) / 400 for 50 < fck ≤ 90 N/mm2

  • η = 1.0 for fck ≤ 50 N/mm2

    = 1.0 − (fck − 50) / 200 for 50 < fck ≤ 90 N/mm2

For design in accordance with:
  • UK NA, Irish NA, Malaysian NA, Singapore NA, Finnish NA, Norwegian NA:

    γC = 1.5

    αcc = 0.85

  • EC2 Recommendations, Swedish NA:

    γC = 1.5

    αcc = 1.0

IF K ≤ K' THEN compression reinforcement is not required.

Calculate the lever arm, z, from:

z = min(0.5 · d · [1 + (1 − 2 · K / (η · αcc / γC))0.5], 0.95 · d)

The area of tension reinforcement required is then given by:

Ast,reqd = MEd / (fyd · z)

where

  • fyd = fyk / γS
  • γS = the NDP partial safety factor for reinforcement

The depth to the neutral axis, xu, is given by:

xu = 2 · (d − z) / λ

For design in accordance with:
  • UK NA, EC2 Recommendations, Irish NA, Malaysian NA, Singapore NA, Finnish NA, Norwegian NA, Swedish NA:

    γS = 1.15

IF K > K' THEN compression reinforcement is required.

Calculate the depth to the neutral axis from:

xu = d · (δ − k1) / k2 for fck ≤ 50 N/mm2

xu = d · (δ − k3) / k4 for fck > 50 N/mm2

Calculate the stress in the reinforcement from:

fsc = min(Es · εcu3 · (1 − (d2 / xu)), fyd)

where d2 = the distance from the extreme fibre in compression to the center of gravity of the compression reinforcement

Calculate the limiting bending strength, M', from:

M' = K' · fck · bw · d2

Calculate the lever arm from:

z = 0.5 · d · [1 + (1 − 2 · K' / (η · αcc / γC))0.5]

The area of compression reinforcement required, As2,reqd, is given by:

As2,reqd = (MEd − M') / (fsc · (d − d2))

The area of tension reinforcement required, Ast,reqd, is given by:

Ast,reqd = M' / (fyd · z) + As2,reqd · fsc / fyd

Submit

Table of Contents