The deflection of reinforced concrete beams is not directly calculated and the serviceability of the beam is measured by comparing the calculated limiting span/effective depth ratio L / d to the maximum allowable values as given by:1
IF ρ ≤ ρ0
(L / d)max = Kss · f1 · f2 · (11 + 1.5 · (fck)1/2 · (ρ0 / ρ) + 3.2 · (fck)1/2 · ((ρ0 / ρ) − 1)3/2) · (500 · Ast,prov / (fyk · Ast,reqd))
IF ρ > ρ0
(L / d)max = Kss · f1 · f2 · (11 + 1.5 · (fck)1/2 · (ρ0 / (ρ − ρ')) + (1/12) · (fck)1/2 · (ρ' / ρ0)1/2) · (500 · Ast,prov / (fyk · Ast,reqd))
where
- ρ = the designed tension reinforcement ratio at mid-span (or at support for cantilevers) required to resist bending
= Ast,reqd / (bw · d) for rectangular beams
= Ast,reqd / (beff · d) for flanged beams
- ρ' = the designed compression reinforcement ratio at mid-span (or at support for cantilevers) required to resist bending
= As2,reqd / (bw · d) for rectangular beams
= As2,reqd / (beff · d) for flanged beams
- Ast,reqd = the designed area of tension reinforcement at mid-span (or at support for cantilevers) required to resist bending
- Ast,prov = min(the area of tension reinforcement provided at mid-span (or at support for cantilevers), f3 · Ast,reqd)
- As2,reqd = the designed area of compression reinforcement at mid-span (or at support for cantilevers) required to resist bending
- f1 =
- 1.0 for rectangular beams
- 1.0 for flanged beams with beff / bw ≤ 3.0
- 1.8 for flanged beams with beff / bw > 3.0
- f2 =
- 1.0 IF Leff ≤ 7 m
- 7 / Leff IF Leff > 7 m with Leff in meter units
- Leff = the length of the beam between the center of its supports2
- f3 = an NDP factor as given below
- Kss = the structural system factor which is an NDP and is given below
-
UK NA
as per Table NA.5 Note 6 the absolute value of span/depth may not exceed 40K.
-
EC2 Recommendations, Finnish NA, Norwegian NA, Swedish NA
the NDP value of f3 is given by:3
f3 = 1.5
-
UK NA, Irish NA, Malaysian NA, Singapore NA
the NDP value of f3 is given by:4
f3 = 1.5
-
UK NA, EC2 Recommendations, Irish NA, Malaysian NA, Singapore NA, Norwegian NA, Swedish NA
the NDP value of Kss is given by the following table:
Span Detail LH End Fixity RH End Fixity Kss LH End Span Fixed Fixed 1.3 Fixed Pinned 1.0 Pinned Fixed 1.3 Pinned Pinned 1.0 Internal Span Fixed Fixed 1.5 Fixed Pinned 1.3 Pinned Fixed 1.3 Pinned Pinned 1.0 RH End Span Fixed Fixed 1.3 Fixed Pinned 1.3 Pinned Fixed 1.0 Pinned Pinned 1.0 Cantilever 0.4 -
Finnish NA
the NDP value of Kss is given by the following table:
Span Detail LH End Fixity RH End Fixity Kss LH End Span Fixed Fixed 1.0 Fixed Pinned 0.8 Pinned Fixed 1.0 Pinned Pinned 0.8 Internal Span Fixed Fixed 1.2 Fixed Pinned 1.0 Pinned Fixed 1.0 Pinned Pinned 0.8 RH End Span Fixed Fixed 1.0 Fixed Pinned 1.0 Pinned Fixed 0.8 Pinned Pinned 0.8 Cantilever 0.3
Footnotes